Parameter Description
Parameter Description
106
(3) Three-wire control mode 2 (with self maintaining function):K1: STOP signal, normally closed. If it is
open, the inverter will stop. K2: RNU signal, normally open, and the pulse signal are active.
(4) Three-wire control mode2 (with self maintaining function):K1: STOP signal, normally close. If K1 is
opened, the inverter will be stopped. K2: RNU signal, normally opened, and the pulse signal is active.
If the external terminal corresponds to the parameters settings for 39, the motor will stop until the
user starts again when reversing.
5. At the external mode, the programmed operation mode is chosen when PO is on. Terminal STF becomes
the start signal. When STF is on, the inverter begins to run at the programmed operation mode at the first
section. When STF is off, the inverter stops running, and STR becomes the pause signal. When STR is
on, the inverter pauses and continues to run at the section where the inverter paused when STR is off. For
details, please refer to P.100, P.101~P.108, P.111~P.118, P.121~P.123 and P.131~P.138.
6. At the external mode, the manually operation circle mode is chosen when MPO is on. For details, please
refer to P.100, P.101~P.108, P.111~P.118, P.121~P.123 and P.131~P.138.
7. Frequency set by pulse means: the inverter measure and calculate the ON times and OFF times in each
PWM cycle, as its frequency directive.(the admissible PWM cycle is within 0.9ms~1100ms)