Parameter Description
Parameter Description
142
5.75 Sliding Compensation Gain (P.320)
P320” Sliding compensation gain”
Parameter
Factory setting
Setting range
Remarks
320
80%
0~200%
---
<
Setting
>
● P320 is used to set sliding compensation gain coefficient. The bigger the value is set, the bigger the
sliding compensation is.
5.76 Torque Compensation Filter (P.321)
P.321” Torque compensation filter coefficient”
Parameter
Factory setting
Setting range
Remarks
321
16
0~32
---
< Setting >
● P.321 is used to set torque compensation filter coefficient. The bigger the value is set, the bigger
the filter is.
5.77 Parameter Copy Function (Pr.CP and Pr.CA) (DU06 operation panel
needs to be purchased)
Pr.CP “Parameter copy readout”
Pr.CA “Parameter copy write-in”
● Parameter copy function is valid only when the motor is stop, P.77=0, and under the PU mode. If several inverters
need set same parameter values, just only set one inverter parameters, then use Pr.CP and Pr.CA to quickly copy
the values to other inverters.
● Parameter copy operation procedure:
1. When the first inverter is in the PU mode, press
to switch to the parameter setting mode. Rotate
until
is displayed, and it will displays “0” after pressing
. Then rotate
to change the value to “1”
and write in by pressing
. The screen will display the parameter number one by one. Those indicating the
parameters are copied from the inverter to the operation panel. When the parameter copying is completed the
screen will display
and flickering.
2. When the second inverter is in the PU mode, after
is read out, the screen of the panel will display
the initial value “0”. Rotate
to change the value to “1” and write in by pressing
. The screen will
display the parameter number one by one. Those indicating the parameters are copied from the operation panel
to the inverter. When the parameter copying is completed the screen will display
and flickering.