Appendix 1 Parameter list
Parameter List
158
Parameter
number
Name
Setting range
Minimum
setting unit
Default value
User setting
value
Reference
page
P.196
Frequency corresponds to the
minimum input current/voltage
across terminal 4-5
0~60Hz
0.01Hz
0Hz
P126
P.197
Frequency corresponds to the
maximum input current /voltage
across terminal 4-5
0~650Hz
0.01Hz
50Hz/60Hz
(
Note
)
P126
P.198
Minimum input current/voltage
across terminal 4-5
0~20
0.01
0
P126
P.199
Maximum input current/voltage
across terminal 4-5
0~20
0.01
0
P126
P.223 Analog feedback bias pressure
0~100%
0.1
0%
P117
P.224 Analog feedback gain pressure
0~100%
0.1
100%
P117
P.225 Panel command
0~100%,9999
0.1
20%
P117
P.226 The paver function selection
0, 1
1
0
P127
P.227
The limit time of positive
rotation
0~3600s
0.1 s
0
P127
P.228
The limit time of reverse
rotation
0~3600s
0.1 s
0
P127
P.229
Backlash
compensation
and
acceleration/deceleration
interrupted for waiting function
selection
0~2
1
0
P128
P.230
The acceleration interrupt
frequency
0~650Hz
0.01Hz
1Hz
P128
P.231 The acceleration interrupt time
0~360s
0.1s
0.5s
P128
P.232
The deceleration interrupt
frequency
0~650Hz
0.01Hz
1Hz
P128
P.233 The deceleration interrupt time
0~360 s
0.1s
0.5s
P128
P.234
Triangular wave function
selection
0~2
1
0
P130
P.235 Maximum amplitude
0~25%
0.1%
10%
P130