Appendix 1 Parameter table
Appendix 168
Parameter
Number
Group
Name
Setting Range
Default
Page
P.149
04-14
Speed 15
Same as 04-03
99999
P.150
10-08
Restart mode selection
X0:No frequency search.
0
X1:Reserved
X2:Decrease voltage mode
0X:Power on once.
1X:Start each time.
2X:Only instantaneous stop and restart
P.151
10-03
Zero-speed control
function selection
0: Off.
0
1: DC voltage braking
P.152
10-04
Voltage at zero-speed
control
0~30.0%
5.0%
P.153
07-10
Communication alarm
action
0:Alarm and stop freely
1
1:No alarm and continuing to operation
P.154
07-07
Modbus communication
format
0:1、7、N、2 (Modbus, ASCII)
4
1:1、7、E、1 (Modbus, ASCII)
2:1、7、O、1 (Modbus, ASCII)
3:1、8、N、2 (Modbus, RTU)
4:1、8、E、1 (Modbus, RTU)
5:1、8、O、1 (Modbus, RTU)
6:1、8、N、1 (Modbus, RTU)
P.155
06-08
Over torque detection
level
0~200.0%
0.0%
P.156
06-09
Over torque detection
time
0~60.0s
1.0s
P.157
03-17
Digital input terminal filter
time
0~2000
4
P.158
03-18
Digital input terminal
enable when power on
0: When power on digital terminals work directly
0
1: When power on digital terminals work after switch
off then on
P.159
10-17
Energy-saving control
function
0: Off.
0
1: Energy-saving mode.
P.161
00-07
Multi-function display
0: Output AC voltage (V)
0
1: DC bus voltage. (V)
2: Inverter temperature rising accumulation rate (%)
3: Target pressure of the constant pressure system
(%)
4: Feedback pressure of the constant pressure system
(%)
5: Running frequency (Hz)
6: Electronic thermal accumulation rate (%)
8: Signal value (mA) of 3-5 input terminals (mA/V).
9: Output power (kW).