background image

 

 
 
 

IFS MC250-4T/ Series  
User Manual 

P/N 1072574 • REV 00.05 • ISS 30JAN13 

Summary of Contents for IFS MC250-4T Series

Page 1: ...IFS MC250 4T Series User Manual P N 1072574 REV 00 05 ISS 30JAN13 ...

Page 2: ...nt generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications You are cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment ACMA compliance Notice This is a Class A pro...

Page 3: ...scription 3 Front Panel 4 LED Indicators 5 Converter Top Panel 5 Wiring the Power Inputs 5 Wiring the Fault Alarm Contact 6 Mounting Installation 7 Installation Steps 11 Switch Operation 12 Troubleshooting 14 Specifications 15 Compatible SFP Modules 17 RJ45 Pin Assignments 17 Contacting Technical Support 19 ...

Page 4: ......

Page 5: ... series Industrial Ethernet Media converter also supports flow control and back pressure in half duplex to eliminate packets loss Package Contents Check the contents of your package for the following parts MC250 4T series module x1 User s Manual x1 DIN Rail Kit x 1 Wall Mount Kit x 1 If any of these items are missing or damaged please contact your distributor or IFS sales rep immediately If possib...

Page 6: ... FX Supports Auto negotiation and 10 100Mbps Half Full duplex mode for each copper port High performance store and forward architecture broadcast storm control runt CRC filtering eliminates erroneous packets to optimize the network bandwidth Prevents packet loss with back pressure Half Duplex and IEEE 802 3x PAUSE frame flow control Full Duplex Backplane Switching Fabric MC250 4T 1FM 1FS 1Gbps MC2...

Page 7: ...itching fabric these Industrial Fast Ethernet Switches can handle extremely large amounts of data in a secure topology linking to a backbone or high capacity servers The Industrial Fast Ethernet Switch has 2K MAC address table and offers wire speed packets transfer performance without risk of packet loss The stable throughput of the device makes it ideal for most network environments All RJ 45 cop...

Page 8: ...4 IFS MC250 4T XXX Series User Manual Front Panel The figure below shows the MC250 4T 1FM 1FS and the MC250 4T 2S ...

Page 9: ...he network at 100Mbps Off indicates that the Switch is successfully connected to the network at 10Mbps Fiber Optical LNK ACT Green Copper Lit indicates that the link through that port is successfully established Blink indicates that the Switch is actively sending or receiving data over that port Converter Top Panel The top panel of the Industrial Media Converter consists of one terminal block conn...

Page 10: ...e wires from disconnecting 1 2 3 4 5 6 Power 1 Fault Power 2 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below Inserting the wires the MC250 4T will detect the fault status of the power failure and then forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts ...

Page 11: ... This section describes how to mount the MC250 4T and make connections to it Please read the following sections and perform the procedures in the order presented Note In the installation steps below this Manual uses the IFS 8 Port Industrial Gigabit Switch GE DSGH 8 as an example However the steps for any IFS Industrial Switch Industrial Media Converter are similar Insert the wires into the fault ...

Page 12: ...unting to a DIN Rail The DIN Rail kit comes assembled on the MC250 4T out of the box Please refer to following figures to hang the MC250 4T on a DIN Rail 1 Lightly press down and push the bottom of the DIN Rail connector mount into the track ...

Page 13: ...to following procedures to remove the MC250 4T from the track 4 Lightly press down and pull the bottom of DIN Rail connector mount to remove it from the track Mounting to a Wall To install the MC250 4T on the wall please follows the instructions described below 1 Loosen the screws to remove the DIN Rail from the Media Converter ...

Page 14: ...Series User Manual 2 Place the wall mount plate on the rear panel of the MC250 4T 3 Assemble the wall mount plate on the MC250 4T 4 Use the hook holes at the corners of the wall mount plate to hang the MC250 4T on the wall ...

Page 15: ...for meaning of LED lights Step 5 Prepare the twisted pair straight through Category 5 cable for Ethernet connection Step 6 Insert one side of Category 5 cables into the Industrial Fast Ethernet Switch Ethernet port RJ 45 port and the other side to the network devices Ethernet port RJ 45 port ex Switch PC or Server The UTP port RJ 45 LED on the Industrial Fast Ethernet Switch will illuminate when t...

Page 16: ...ustrial Fast Ethernet Switch it will also check the destination address besides the source address learning The Industrial Fast Ethernet Switch will lookup the address table for the destination address If not found this packet will be forwarded to all the other ports except the port which this packet comes in And these ports will transmit this packet to the network it is connected to If found and ...

Page 17: ...f the Industrial Fast Ethernet Switch the source address and corresponding port number of each incoming and outgoing packet are stored in a routing table This information is subsequently used to filter packets whose destination address is on the same segment as the source address This confines network traffic to its respective domain reducing the overall load on the network The Industrial Fast Eth...

Page 18: ... negotiation mode by default and if the partner is set to half duplex then the performance will become bad Link LED is light but the traffic is irregular Solution Check that the attached device is not set to dedicate full duplex Some devices use a physical or software switch to change duplex modes Auto negotiation may not recognize this type of full duplex setting Why does the Industrial Fast Ethe...

Page 19: ...ower Requirement 12 48V DC Redundant power with polarity reverse protection function Power Consumption Dissipation 13 7 Watts 46BTU Installation DIN Rail Kit and Wall Mount Ear Switch Specification Switch Processing Scheme Store and Forward Address Table 2K entries Buffer 1Mbit Flow Control Back pressure for Half duplex IEEE 802 3x Pause Frame for Full duplex Switch Fabric 1Gbps Throughput Packet ...

Page 20: ...0Base FX Cable Mode Multi Mode 50 125μm fiber 62 5 125μm fiber Single Mode 9 125μm fiber Fiber Optical Distance Depend on SFP Module Dimensions W x D x H 135mm x 97mm x 32mm Weight 442g Power Requirement 12 48V DC Redundant power with polarity reverse protection function Power Consumption Dissipation 16 Watts 54BTU Installation DIN Rail Kit and Wall Mount Ear Switch Specification Switch Processing...

Page 21: ...erating Operating 5 to 90 Storage 5 to 90 Non condensing Regulation Compliance FCC Part 15 Class A CE Compatible SFP Modules When connecting to other Ethernet equipment such as a Router Bridge Switch or Hub please refer to that device s Technical Manual RJ45 Pin Assignments 10 100Mbps 10 100Base TX RJ 45 Connector pin assignment Contact MDI Media Dependant Interface MDI X Media Dependant Interface...

Page 22: ...ing The following figure shows the pin allocation and color of a straight cable and connection of a crossover cable Please make sure your connected cables are with same pin assignment and color as above picture before deploying the cables into your network ...

Page 23: ...ation Please make sure you have the requested diagnostic or log files ready before you contact us by phone or go to www interlogix com customer support Technical Support Europe Middle East and Africa W Select Contact Us at www utcfssecurityproducts eu North America T 1 855 286 8889 E techsupport interlogix com Australia E techsupport interlogix au ...

Reviews: