Main
code
Sub
code
Item
Contents
Adjustment value
Ref. page
Default
Adjustment
scope
1
Maintenance cycle
setting
When the sub code is entered, the LCD shows the following
display and the current maintenance cycle set value is dis-
played on the copy quantity display. With the RPL on, select
the desired set value with the 10-key and press the START
key, and the maintenance cycle will be stored.
0
0
∼
6
—
SIMULATION NO. 21-1
SELECT MAINTENANCE CYCLE (0~6)
0. 100K 1. 200K
2. 50K 3. 20K 4. 10K 5. 5K
6. NONE
If the maintenance cycle is set to "0
∼
5," when the copy quan-
tity count reaches the set value, the following message is dis-
played to show that the maintenance is required.
READY TO COPY.
MAINTENNANCE REQUIRED : c
(MAINTENNANCE
CODE)
When the maintenance cycle is set to "6," the maintenance
cycle is not set.
The relationship between the maintenance code (double un-
derlined) in the above message and the simulation set values
is shown in the table below.
Sim 21-1
set value
Maintenance
cycle
Maintenance
code
0
100K
A
1
200K
B
2
50K
C
3
20K
D
4
10K
E
5
5K
F
6
none
—
22
When the main code is inputted, the LCD shows the following
display and a sub code blinks on the copy quantity display.
With the RPL on, enter the desired sub code and press the
START key to start the operation.
SIMULATION NO. 22
INPUT 1~5
1. COUNTER DATA DISPLAY.
2. JAM COUNTER DATA DISPLAY.
3. ERROR COUNTER DATA DISPLAY.
4. KEY OPERATOR CODE DISPLAY.
5. ROM VERSION DATA DISPLAY.
1
Counter display
When the sub code is entered, the LCD shows "Page 1" as
shown below. In this case, when the scroll (
→
) key is pressed,
the LCD shows "Page 2." Pressing the scroll key shows "Page
1" and "Page 2" alternately.
—
—
—
9 – 13