Main
code
Sub
code
Item
Contents
Adjustment value
Ref. page
Default
Adjustment
scope
43
When the main code number "43" is entered, the LCD shows
the stand-by and single copy fusing temperature adjustment
level setting screen and the RPL lights up. The current set
value is displayed on the copy quantity display. Enter the
desired set value and press the PRINT switch to store it. When
the scroll key is pressed with the screen displayed, the duplex
copy fusing temperature level setting screen is shown, and the
set value is displayed on the coy quantity display. Enter the
desired set value similarly.
Single mode
3
Double mode
Japan: 7
EX : 3
—
—
Stand-by and single copy fusing temperature adjustment level
setting screen
Fusing temperature
control temperature
setting
(Note) When the adjustment value is "0," the adjustment
value returns to the default value "3" (200°C).
↓
➞
KEY
↑
Duplex copy fusing
temperature
adjustment level
setting
(Note) When the adjustment value is "0," the adjustment
value returns to the default value: "3" (180°C) for out-
side Japan, "7" (200°C) for Japan.
44
When the main code is inputted, the LCD shows the following
display and a sub code blinks on the copy quantity display.
With the RPL on, enter the desired sub code and press the
START key to start the operation.
SIMULATION NO. 44
INPUT 1~9
1. DISABLE/ENABLE PROCESS-CONTROL SETUP.
2. DMS POWER SETUP.
3. IDS POWER SETUP.
4. PROCESS CONTROL DATA BASE ENTRY.
5. (NO PROGRAM)
6. (NO PROGRAM)
7. DMS/IDS SENSOR LEVEL CHECK.
8. (NO PROGRAM)
9. PROCESS CONTROL DATA DISPLAY.
SIMULATION NO. 43
[1
→
1, 2
→
1]
INPUT (1~5)
1. 190°C
2. 195°C
3. 200°C
4. 205°C
5. 210°C
[1
→
2, 1
→
2]
INPUT 1~9
1. 170°C
2. 175°C
3. 180°C
4. 185°C
5. 190°C
6. 195°C
5. 200°C
5. 205°C
6. 210°C
[1
→
2, 2
→
2] SETTING : PRESS
➞
KEY.
SIMULATION NO. 43
[1
→
1, 2
→
1]
INPUT (1~5)
1. 190°C
2. 195°C
3. 200°C
4. 205°C
5. 210°C
[1
→
2, 1
→
2]
INPUT 1~9
1. 170°C
2. 175°C
3. 180°C
4. 185°C
5. 190°C
6. 195°C
5. 200°C
5. 205°C
6. 210°C
[1
→
1, 2
→
1] SETTING : PRESS
➞
KEY.
9 – 27