Main
code
Sub
code
Item
Contents
Adjustment value
Ref. page
Default
Adjustment
scope
1
Duplex width guide
adjustment
When the sub code is entered, the LCD shows the following
display and the currently set value of the intermediate tray
alignment plate adjustment value is displayed on the copy
quantity display. With the RPL on, enter the set value with the
10-key pad and press the START key to store it. The alignment
plate will move to 8.5" x 11" size if the destination is "INCH,"
and to A4 size if the destination is "AB."
"50" is the reference value of the set value. If the set value is
greater than 50, the alignment plate width becomes smaller. IF
smaller than 50, the alignment plate width becomes greater. (1
count = 0.57mm)
—
—
—
SIMULATION NO. 52-1
DUPLEX WIDTH GUIDE ADJUSTMENT.
INPUT DATA. (1~99)
*
When the set value is "0," the adjustment is the same as
that of "50."
2
Duplex bach stop
guide adjustment
When the sub code is entered, the LCD shows the following
display and the currently set value of the intermediate tray rear
plate adjustment value is displayed on the copy quantity dis-
play. With the RPL on, enter the set value with the 10-key pad
and press the START key to store it. The alignment plate will
move to 8.5" x 11" size if the destination is "INCH," and to A4
size if the destination is "AB."
"50" is the reference value of the set value. If the set value is
greater than 50, the rear plate goes apart from the home posi-
tion. If smaller than 50, the rear plate comes to the home
position. (1 count = 0.57mm)
SIMULATION NO. 52-2
DUPLEX BACH STOP GUIDE ADJUSTMENT.
INPUT DATA. (1~99)
*
When the set value is "0," the adjustment is the same as
that of "50."
4
ADU paper holding
time adjustment
When sub code "4" is entered, the LCD shows the following
display, and the currently set adjustment value of "DPFWS ON
– PRFC ON" time in ADU paper feed is displayed on the copy
quantity display. When the RPL is ON, enter the set value with
the 10-key pad and press the START key to store it.
The default value is "35", and 1 count corresponds to 10msec.
SIMULATION NO. 52-4
ADU PAPER FEED TIMING.
INPUT DATA. (1~99)
Sim.52-4
RP L
DPFWS
DPFC
9 – 40