Main
code
Sub
code
Item
Contents
Adjustment value
Ref. page
Default
Adjustment
scope
Note 1: ( ) shows the input range of adjustment value.
Note 2: When the adjustment value is set to "0," the adjust-
ment is similar to that of the default value.
When this simulation is executed, the machine goes into warm-
up state. At this time, the LCD shows the following message.
The correction value of RRC front warp quantity in manual
paper feed of small size paper is displayed on the copy quan-
tity display.
SIMULATION NO. 51-5
RRC PAPER BUCKLE REVISION.
(BYPASS TRAY;5.5
×
8.5, A5)
INPUT DATA. (0~20)
At this time, the correction value of RRC front warp quantity in
manual paper feed of small size paper can be entered
(changed). After entering the value, press the PROGRAM ON
key to store it.
When the warm up is completed, copying ca be made.
52
(Simulation No. 51)
When the sub code "6" is entered, the LCD shows the follow-
ing display. The currently set value (the correction value) of
RRC front warp amount in manual paper feed of small size
paper is displayed on the copy quantity display. When the RPL
is on, enter the correction value and press the PRINT switch to
store it.
SIMULATION NO. 51-6
RRC PAPER BUCKLE REVISION.
(BYPASS TRAY;5.5
×
8.5, A5)
INPUT DATA. (0~20)
When the main code is inputted, the LCD shows the following
display and a sub code blinks on the copy quantity display.
With the RPL on, enter the desired sub code and press the
START key to start the operation.
SIMULATION NO. 52
INPUT 1~2
1. DUPLEX WIDTH GUIDE ADJUSTMENT.
2. DUPLEX BACH STOP GUIDE ADJUSTMENT.
3. (NO PROGRAM)
4. ADU PAPER FEED TIMING
: Manual feed tray
*
LCD DISPLAY
COPY QUANTITY DISPLAY
SCROLL KEY
ON
: Tray 1
SCROLL KEY
ON
: Tray 2
SCROLL KEY
ON
: Tray 3
SCROLL KEY
ON
: Tray 4
SCROLL KEY
ON
: LCC
SCROLL KEY
ON
51A MFT (1~99)
* *
51B CAS1 (1~99)
51C CAS2 (1~99)
51D CAS3 (1~99)
51E CAS4 (1~99)
51F LCC (1~99)
* * *
* * *
* * *
* * *
* * *
: Intermediate tray
51 ADU (1~99)
* * *
9 – 39