Main
code
Sub
code
Item
Contents
Adjustment value
Ref. page
Default
Adjustment
scope
2
Lead edge
adjustment (simple
type)
When this simulation is executed, the machine starts warming
up and the LCD shows the following display. The currently set
value of "50_L1" (Lead edge shift at 200% copy) is displayed
on the copy quantity display.
—
—
P. 8 – 17
SIMULATION NO. 50-2
INPUT_A (0~999)
Enter the value of "lead edge shift at 200% copy" with the
10-key pad and press the PROGRAM ( P ) key to store it.
Press the scroll key (
→
) to scroll the message display on the
LCD and the copy quantity display as follows:
50_L2
→
50C
→
50D
→
50E
→
50_L1
→
50_L2
→
The set value can be stored or changed in the same manner
as in "50A."
After completion of warming up, copying is allowed.
Note 1: ( ) shows the input range of adjustment value.
Note 2: When "50_L1" is entered, the copy magnification ratio
is automatically set to 200%.
[Adjustment procedure]
1. Set L1 and L2 to "0."
2. Put a scale on the original table.
3. Make a copy at 200%.
4. Make a copy at 100%.
5. Set the screen to "INPUT_L1" display, and enter the lead
edge shift at 200% copy with the 10-key pad.
(Example) IN the case of 35.5mm, enter "355."
6. Set the screen to "INPUT_L2" display, and enter the lead
edge shift at 100% copy with the 10-key pad.
(Example) In the case of 35.5mm, enter "355."
7. Press the START key to make a copy.
3
Lead edge
adjustment value
input
When the sub code is entered, the LCD shows the following
display and the currently set value of "50A" (distance between
MHP to the image lead edge) is displayed on the copy quantity
display. With the RPL on, enter the set value with the 10-key
pad and press the START key to store it.
—
—
—
SIMULATION NO. 50-3
INPUT_D (0~99)
Press the scroll key (
→
) to scroll the message display on the
LCD and the copy quantity display as follows:
50B
→
50C
→
50D
→
50E
→
50A
→
50B
→
The set value can be stored or changed in the same manner
as in "50A."
: Lead edge shift at 200% copy (L1)(1 count = 0.1mm)
*
LCD DISPLAY
COPY QUANTITY DISPLAY
SCROLL KEY
ON
: Lead edge shift at 100% copy (L2)(1 count = 0.1mm)
SCROLL KEY
ON
:
SCROLL KEY
ON
: Lead edge void amount data(1 count = 0.47mm)
SCROLL KEY
ON
: Read edge void amount data (1 count = 0.47mm)
INPUT_L1(0~999)
* *
INPUT_L2(0~999)
INPUT_C (1~20)
INPUT_D (0~20)
INPUT_E (0~20)
* * *
* * *
* * *
* * *
9 – 34