Main
code
Sub
code
Item
Contents
Adjustment value
Ref. page
Default
Adjustment
scope
4
No. 4/5 mirror
characteristics
value input
When the sub code is entered, the LCD shows the following
display and the currently set value of "48D" (Focus correction
value data) is displayed on the copy quantity display. With the
RPL on, enter the set value with the 10-key pad and press the
START key to store the set value.
—
—
—
SIMULATION NO. 48-4
> 48D (1~97)
:
49
48E (1~21)
:
11
48F (1~21)
:
11
Press the scroll key (
→
) to scroll the message display on the
LCD and the copy quantity display as follows:
48E
→
48F
→
48D
→
48E
→
The set value can be stored in the same manner as in "48A."
Note 1: ( ) shows the input range of adjustment value.
Note 2: When the adjustment value is "0," the similar adjust-
ment to the default value is performed.
5
Mirror speed
correction value
input
When the sub code is entered, the LCD shows the following
display and the currently set mirror speed correction data is
displayed on the copy quantity display. With the RPL on, enter
the set value with the 10-keypad to store the value. (1 count =
0.1%)
15
—
—
SIMULATION NO. 48-5
[Adjustment conditions]
Adjustment range: –1.4%
∼
+1.5%
Adjustment value input range: 1
∼
30 [0.0% when the adjust-
ment value is 15. (Default: 15)]
Note: When the adjustment value is "0," the similar adjust-
ment to the default is performed.
: Focusing correction value[Default: 49]
*
LCD DISPLAY
COPY QUANTITY DISPLAY
SCROLL KEY
ON
: Zoom correction value (Reduction)[Default: 11]
SCROLL KEY
ON
: Zoom correction value (Enlargement)[Default: 11]
48_D (100%)
* *
48_E (50%)
48_F (200%)
* * *
* * *
1
30
-1.4%
+1.5%
15
0.0%
-0.1%
G H
+0.1%
Changing rate of scanning speed