(7) Slide the empty toner cartridge back along the
guides and remove it.
•
The cartridge opening will be closed as it is moved back along the
guides.
(8) Close the toner hopper cover.
NOTE:
Add only one cartridge of toner.
Note
Supply only one toner cartridge for one time. If two or more
cartridges are supplied, toner will flow out.
10. Initial toner density level registration
(AUtomatic developer adjustment)
1
Insert the developing unit into the copier and press it onto the
photoconductor drum with the pressure lever.
2
Check that the process unit, the transport unit, and the fusing unit
are securely installed.
3
Close the front covers (L and R).
4
Connect the power plug and turn on the power switch.
5
Execute simulation 25-02.
The drum motor rotates and the developing unit is driven for 3
minutes. After 3 minutes,the initial toner density level is sensed by
the toner density sensor and stored in the memory of the main
PWB.
Procedure: C
→
ë
→
0
→
ë
→
2
5
→
START
→
2
→
START
[Note]
•
For automatic developer adjustment, check the following and per-
form it.
•
Check that the cleaner blade is in close contact with the photocon-
ductor.
•
Check that each charger unit is installed.
6
Cancel the simulation mode.
11. Initial system setting
(1) Destination setting
Check the destination setting with the simulation.
1
Execute simulation 26-6.
SIMULATION NO. 26-6
[INCH]
0. SEC (ES) 1. SEC 2. SECL 3. OTHER
[AB (B5)]
4. JAPAN 5. OTHER
[AB (A5)]
6. SEEG 7. SUK 8. SCA 9. OTHER
PLEASE SELECT DESTINATION BY
10-KEY PAD.
Option setting for each destination
No. Destination
No. of
trays
LCC
RADF
Original
sensor
unit
Sorter
Toner
save
mode
P21
0
SEC (ES)
3
D
(LT)
F
✕
v
P22
SHUT OFF
1
SEC
3
D
(LT)
F
✕
v
P22
Power save
2
SECL
3
D
(LT)
F
✕
v
P22
Power save
3
INCH, etc.
3
D
(LT)
D
✕
v
P22
Power save
6
SEEG
3
v
v
✕
v
P22
Power save
7
SUK
3
v
v
✕
v
—
Power save
8
SCA
3
v
D
✕
v
P22
Power save
9
A5, etc.
3
v
D
✕
v
P22
Power save
F
: Standard provision
D
: Installed when setting the destination. (Setting changeable)
✕
: Not installed.
v
: Not installed when setting the destination. (Setting changeable)
2
If setting is improper, enter with the 10-keypad and press the
START key to set again.
(2) Option setting
For option setting, follow the procedures below.
1
Execute simulation 26-1.
SIMULATION NO. 26-1
OPTION SETUP.
CODE : RADF
SORTER/STAPLE SORTER
1
:
F
F
2
:
F
✕
3
:
✕
F
4
:
✕
✕
F
:
SETTING
✕
: NO SETTING
PLEASE SELECT BY 10-KEY PAD.
2
Check the option which is to be installed to the copier. Enter with
the 10-keypad, and press the START key to set.
3
When using the large capacity cassette (LCC, SF-C52), execute
simulation 26-2 to set the paper size.
SIMULATION NO. 26-2
LCC SIZE SETTING
0. NO LCC
1. 8.5
″
×
11
″
(216
×
279)
2. A4
3. B5
For the four-stage trays, there is no paper size setting for each tray.
(Setting is made only with the size sensor.)
1
2
3
4
5
6
7
8
9
6 – 9