Main
code
Sub
code
Item
Contents
Adjustment value
Ref. page
Default
Adjustment
scope
53
When the main code is inputted, the LCD shows the following
display and a sub code blinks on the copy quantity display.
With the RPL on, enter the desired sub code and press the
START key to start the operation.
SIMULATION NO. 53
01~04: ORIGINAL STOP POINT SETUP.
NOM
THIN
SIMP
DUP
1
*
*
2
*
*
3
*
*
4
*
*
05~06: (NO PROGRAM)
07~10: RADF SENSOR ADJUSTMENT.
07.
REGIST 08.
TIMING 09.
EXIT/REVERSAL
10. EMPTY
1
Original stop
position adjustment
Used to adjust the original (normal paper) stop position in the
RADF in the single copy mode.
—
—
—
2
Original stop
position adjustment
Used to adjust the original (normal paper) stop position in the
RADF in the duplex copy mode.
—
—
—
3
Original stop
position adjustment
Used to adjust the original (thin paper) stop position in the
RADF in the single copy mode.
—
—
—
4
Original stop
position adjustment
Used to adjust the original (thin paper) stop position in the
RADF in the duplex copy mode.
When this simulation is executed, the RPL lights up and the
currently set adjustment value is displayed on the copy quan-
tity display. Enter the set value with the 10-key pad and press
the START key to store it.
The adjustment value range is 0
∼
15. With "8" as the refer-
ence value, if the adjustment value is smaller than the refer-
ence value, the stop position comes to the paper feed side. If
the adjustment value is greater than the reference value, the
stop position comes to the paper exit side.
Adjustment value
Adjustment value
0
–8.000mm
Paper feed side
1
–7.000mm
2
–6.000mm
3
–5.000mm
4
–4.000mm
5
–3.000mm
6
–2.000mm
7
–1.000mm
8
0.0 (Reference)
9
+1.000mm
Paper exit side
10
+2.000mm
11
+3.000mm
12
+4.000mm
13
+5.000mm
14
+6.000mm
15
+7.000mm
(Reference: Adjustment value =8)
7
RADF resist sensor
adjustment
Used to adjust the threshold value of the RADF resist sensor
sensing level.
—
—
—
8
RADF timing
sensor adjustment
Used to adjust the threshold value of the RADF timing sensor
sensing level.
—
—
—
9
RADF paper exit
sensor adjustment
Used to adjust the threshold value of the RADF paper exit
sensor sensing level.
—
—
—
9 – 41