Main
code
Sub
code
Item
Contents
Adjustment value
Ref. page
Default
Adjustment
scope
Sensor
Switch
CSSn4
CSSn3
CSSn2
CSSn1
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
A3
OFF
OFF
ON
OFF
A4
OFF
OFF
ON
ON
8.5" x 11"
OFF
ON
OFF
OFF
B4
OFF
ON
OFF
ON
8.5" x 14"
OFF
ON
ON
OFF
11" x 17"
OFF
ON
ON
ON
5.5" x 8.5"
ON
OFF
OFF
OFF
B5
ON
OFF
OFF
ON
Ex
ON
OFF
ON
OFF
A5
ON
OFF
ON
ON
F4
ON
ON
OFF
OFF
A4R
ON
ON
OFF
ON
B5R
ON
ON
ON
OFF
8.5" x 11"R
ON
ON
ON
ON
Ex
7
When the main code is inputted, the LCD shows the following
display and a sub code blinks on the copy quantity display.
With the RPL on, enter the desired sub code and press the
START key to start the operation.
SIMULATION NO. 7
INPUT 1~7
1. COPIER AGING TEST MODE.
2. COPIER AGING TEST, MISFEED
DETECTION DISABLED.
3. COPIER AGING TEST, MISFEED
DETECTION, WARM UP, TEMPERATURE
CONTROL DISABLED.
4. WARM UP DISABLED.
5. PROCESS UNIT OPERATION TEST.
6. INTERVAL AGING MODE.
7. INTERVAL AGING MODE.
(NO MISFEED DETECTION)
1
Aging with jam
When the sub code is entered, the machine starts warming up,
and the warm-up time is displayed on the LCD. After comple-
tion of warming up, press the CA key. Perform setting in each
mode, press the START key, and aging will be started.
—
—
—
WARM UP TIME : mm : ss
PLEASE WAIT.
2
Aging without jam
When the sub code is entered, the machine starts warming up,
and the warm-up time is displayed on the LCD. After comple-
tion of warming up, press the CA key. Perform setting in each
mode, press the START key, and aging without paper will be
started. In this case, paper jam is ignored.
—
—
—
WARM UP TIME : mm : ss
PLEASE WAIT.
3
Aging without jam,
without fusing
temperature control
When the sub code is entered, aging is performed without
warm-up and ignoring the heater system trouble and paper
jam. (The heater lamp does not light up.)
—
—
—
9 – 9