PPC communication codes in the trouble mode
Trouble code
Trouble name
Sub code
Content of trouble
U4
ADU trouble
02
ADU alignment plate home position detection trouble
03
ADU rear plate home position detection trouble
U5
RADF trouble
00
Communication rouble between the RADF and the machine
01
Resist sensor trouble
02
Paper reverse sensor trouble
03
Timing sensor trouble
04
Empty sensor trouble
11
Paper feed motor trouble
12
Transport belt motor trouble
L8
AE trouble
01
Full wave signal absence
02
Full wave signal width abnormality
F1
Sorter/staple sorter trouble
04
Indexer lower limit detected.
05
Indexer upper limit detected.
06
Indexer motor trouble
10
Stapler clogging/trouble (staple sorter only)
F2
Process system trouble
31
Photoconductor surface reflecting rate abnormality
32
Drum marking scanning abnormality
33
The grid voltage exceeds the upper or lower limit.
35
In the patch measurement mode, the measured value exceeds the allowable
range.
37
Drum marking sensor gain adjustment trouble
F3
Tray trouble
01
LCC PT disc trouble
02
LCC ascending trouble
03
LCC descending trouble
12
Tray 1 ascending trouble
22
Tray 2 ascending trouble
32
Tray 3 ascending trouble
42
Tray 4 ascending trouble
Trouble codes during execution of simulation
Trouble code
Trouble name
Sub code
Content of trouble
EE
Automatic developer
adjustment
EU
Sensor level input abnormality (under toner)
EL
Sensor level input abnormality (over toner)
L2
Mirror motor system trouble
00
RRC operation trouble
L8
AE system trouble
01
Full wave signal absence
02
Full wave signal width abnormality
03
AE output does not change.
U5
RADF trouble
00
Communication trouble between RADF and the machine.
01
Resist sensor trouble
02
Paper reverse sensor trouble
03
Timing sensor trouble
04
Empty sensor trouble
11
Paper feed motor trouble
12
Transport belt motor trouble
CC
OC original detection
nn
*
1
Original photo sensor trouble
*
1: Sub code shows the trouble position.
Codes other than trouble
Trouble code
Trouble name
Sub code
Content of trouble
CH (Light)
Door open
—
The door switch is OFF.
CH (Blink)
DV unit trouble
—
The DV unit is not installed, the connector is not connected.
PC
Card counter trouble
—
In the case of the card counter model, the card counter is not installed.
– – –
Auditor trouble
—
The auditor is set, but is in ready state.
PF
PC/MODEM trouble
—
In the model with PC/MODEM installed, the copy inhibit command from the host
is received.
9 – 43