Main
code
Sub
code
Item
Contents
Adjustment value
Ref. page
Default
Adjustment
scope
24
When the main code is inputted, the LCD shows the following
display and a sub code blinks on the copy quantity display.
With the RPL on, enter the desired sub code and press the
START key to start the operation.
SIMULATION NO. 24
INPUT 1~7
1. JAM COUNTER DATA CLEAR.
2. ERROR(TROUBLE) COUNTER DATA CLEAR.
3. DUPLEX COUNTER CLEAR.
4. RADF COUNTER DATA CLEAR.
5. STAPLE COUNTER CLEAR.
6. TRAY COUNTER CLEAR.
7. MEMBRANCE DECREASE ADJUSTMENT
CLEAR.
1
Jam counter clear
When the sub code is entered, the LCD shows the jam counter
to be cleared.
—
—
—
SIMULATION NO. 24-1
JAM COUNTER CLEAR.
1. MACHINE 2. RADF 3. BOTH
*
BOTH: Both of MACHINE and RADF.
1. MACHINE JAM COUNTER CLEAR
When "1. MACHINE" is selected in the jam counter selection
screen and the START key is pressed, the LCD shows the
following display.
When "1. YES" is selected in the display and the START key is
pressed, the machine jam counter is cleared and the LCD
returns to the sub code input screen of Sim 24.
When "2. NO" is selected and the START key is pressed, the
counter is not cleared and the LCD returns to the sub code
input screen of Sim. 24.
SIMULATION NO. 24-1
MACHINE JAM COUNTER CLEAR.
ARE YOU SURE ?
1.
YES
2. NO
2. RADF JAM COUNTER CLEAR
When "2. RADF" is selected in the jam counter selection
screen and the START key is pressed, the LCD shows the
following display.
When "1. YES" is selected in the display and the START key is
pressed, the RADF jam counter is cleared and the LCD returns
to the sub code input screen of Sim 24.
When "2. NO" is selected and the START key is pressed, the
RADF counter is not cleared and the LCD returns to the sub
code input screen of Sim. 24.
SIMULATION NO. 24-1
RADF JAM COUNTER CLEAR.
ARE YOU SURE ?
1.
YES 2.
NO
9 – 17