17-15
Setting the Input/Output Conditions
17
Measurement is started when the CCD trigger level is ON.
Measurement is started when a CCD trigger signal is received.
Select one of
the following.
■
Configuration example
Controller
Power supply (24 VDC)
Monitor
Camera 1 (image cap CCD trigger)
Camera 2 (image capturing)
Remote key pad
Data
■
Setting order
CCD trigger
Work
Black White
Edge
Level
Measurement
Personal computer
Setting "17-3 CCD
trigger"
[SYSTEM COND]
1
I/O CONDITIONS (TO NEXT SUB-MENU)
2
COMM.SET
(TO NEXT SUB-MENU)
[I/O CONDITIONS]
1
MEAS INP I/F
PSERIAL CCD-TRIG
2
START CCD SAMPLE AUTO(EDGE LEVL) PARALLEL USB
3
OUTPUT OBJ TYPE PARALLEL USB
(10) Measurement start input = CCD trigger, start sampling = auto, object type change = general
purpose serial, result output = general purpose serial/parallel
The general purpose serial command (code 55
(H)