11-4
Existence Inspection by Point Measurement
11
To the next page
- PAGE CHNG: The items appearing at points
3
to
0
can be scrolled up and down by the up and
down keys, 8 items at a time. Press the SET key, and a test will be executed using
the specified evaluation conditions, and a test results will be displayed.
- P***:
Set the evaluation conditions (WHITE/BLACK) for the point numbers 0 to 255 using
the up and down keys. The points of the selected numbers will blink. WHITE or
BLACK is not displayed for unregistered point numbers.
- TEST: Press the SET key, and a test will be executed using the specified evaluation conditions,
and the test results will be displayed.
Æ
When MODE has been set to AVG-GRAYS
Average light level for each point
You can set the output destinations using the up
and down keys. (NO, Y0 to Y7, C000 to C127)
Not displayed for unregistered point numbers.
You can set the output destinations using the UP
and DOWN keys. (NO, Y0 to Y7, C000 to C127)
Not displayed for unregistered point numbers.
Acceptance (OK/NG) criteria
WHITE: Acceptable when a majority of the inspected
pixels are white.
BLACK: Acceptable when a majority of the inspected
pixels are black.
Ex.: When the point to be inspected is 8 X 8 (64 pixels)
and WHITE is specified, if 33 white pixels are
detected, the point is accepted.
Continued from the previous page
Æ
When MODE has been set to "BINARY"
[EVALUATION COND]
1
PAGE CHNG
[TEST RESULT]
[OUTPUT]
2
P000
WHITE
OK
NO
3
P001
WHITE
OK
NO
4
P002
WHITE
OK
NO
5
P003
WHITE
OK
NO
6
P004
WHITE
OK
NO
7
P005
8
P006
9
P007
0
TEST
EXEC (WITH-POSI.ADJ WITHOUT-POSI.ADJ)
OPS-MENU RETURN LOCK
When you want to select a numeric calculation
- Select "RETURN" to return to the [MEAS COND] menu, and then select
"NUM-CALC" and press the SET key.
-
See "Chapter 15: Numerical Calculations"
When you want to select a PC function
- Select "RETURN" to return to the [MEAS COND] menu, and then select
"OUT-COND" and press the SET key.
-
See "Chapter 16: PC Function"
Return to the [MEAS COND] menu.
-
page 3-16
OPS-MENU RETURN LOCK
[EVALUATION COND]
①
PAGE CHNG
[TEST RESULT]
[OUTPUT]
②
CONDITION SET REST(+
10%)
③
P000
200~210
200
OK
NO
④
P001
200~210
200
OK
NO
⑤
P002
200~210
200
OK
NO
⑥
P003
200~210
200
OK
NO
⑦
P004
200~210
200
OK
NO
⑧
P005
⑨
P006
⑩
P007
⑪
TEST
EXEC(WITH-POSI.ADJ WITHOUT-POSI.ADJ)
-
page 3-16