16-19
PC Function
16
Menu bar
SELECT
Description
Change the output relay address (Y00 to Y15) with the up and down keys
(in units of 8 points).
OSELECT
Change the auxiliary relay address (C000 to C127) with the up and down
keys (in units of 8 points).
ASELECT
Change the final numerical calculation address (AN00 to AN15) with the up
and down keys (in units of 8 points).
F.IMG C1 L
●
LOCK FULL VX.X
■
C1=002.2 OK
C2=100.0 OK
7
1
2
3
4
5
6
The other data displayed is the same as on the MAIN OPS MENU. (See page 1-4.)
1
The ON (
■
) or OFF (
□
) status of the input relays (X00 to X07) is displayed.
2
The ON (
■
) or OFF (
□
) status of the output relays (Y00 to Y15) is displayed.
3
The ON (
■
) or OFF (
□
) status of the auxiliary relays (C000 to C127) is displayed.
4
The results (AN00 to AN15) of the final numerical calculations are displayed.
5
The current timer value is displayed.
6
The current counter value is displayed.
7
Menu bar
[TMR]
TM0:200
TM1:300
TM2:NOT SET
TM3:NOT SET
TM4:NOT SET
TM5:NOT SET
TM6:NOT SET
TM7:NOT SET
[CNTR]
CN0:100
CN1:150
CN2:NOT SET
CN3:NOT SET
CN4:NOT SET
CN5:NOT SET
CN6:NOT SET
CN7:NOT SET
[NUMERIC CALC]
AN00=+
00000250.0 OK
AN01=-
0000030 0.0 OK
AN02=NOT SET
AN03=NOT SET
AN04=NOT SET
AN05=NOT SET
AN06=NOT SET
AN07=NOT SET
OK
SELECT OSELECT ASELECT NCHG-C1 CHG-C2 CHG-EVAL CUSTOM-MNU
OPS-CND MEA-CND SYS-CND CHG-TYPE
(TIPE00) AREA1
MEASURE XXXXXXms 2000-08-15 13:20
X00~07
Y000~007
READY
C000~007
16-5 PC monitor screen
On the MAIN OPS MENU, move the cursor to "CHG-EVAL" item with left and right keys, on the menu bar
at the bottom of the screen, and press the SET key. Then the PC monitor screen will be displayed.
However, before you can display this screen, you have to select item
7
OPS MENU DISPLAY and set
PC-MNTRYES on the [TYPE RUN COND] menu.
-
See page 2-10.