5-4
Degree of Match Inspection
5
Continued from the previous page
You can set the output destinations using the
up and down keys. (No, Y0 to Y7, C000 to
C127)
- Items
7
to
0
are displayed in the "2P-SCH" (2-point search) mode.
-
Page 3-16
[EVALUATION COND]
①
REGISTER NO. 00(0~15)
[TEST RESULT]
[OUTPUT]
②
CONDITION SET RESET AUTO(+
10%)
③
MATCH LVL(MDL0) -10000~+10000
M0=+09000
OK
NO
④
X COORD.(MDL0)000.0~511.0
X0= 000.0
OK
NO
⑤Y
COORD.(MDL0)000.0~479.0
Y0= 000.0
OK
NO
⑥GRAY LVL
(MDL0)
000.0˜255.0
G0= 116.0
OK
NO
⑦
MATCH LVL(MDL1)
-10000˜+10000
M1=+09000
OK
NO
⑧
X COORD.(MDL1)000.0~511.0
X1=+000.0
OK
NO
⑨
Y COORD.(MDL1)000.0~479.0
Y1= 000.0
OK
NO
⑩
GRAY LVL(MDL1)000.0~255.0
G1= 100.0
OK
NO
⑪
TEST
EXEC(WITH-POSI.ADJ WITHOUT-POSI.ADJ)
OPS-MENU RETURN LOCK
F.IMG C1 L
VX.X
(TYPE00)
OK
MEAS XXXXms 1999-08-01 10:30
MEASUREMENT 1 CHK-DEG-MATCH
REGISTER N00(0~15)
M0=+09878 OK
X0= 288.0
OK
Y0= 190.0
OK
G0= 023.0
OK
M1=+09306 OK
X1= 389.0
OK
Y1= 355.0
OK
G1= 023.0
OK
CHG-MEA CHG-REG CHG-RST CHG-C1 CHG-C2 CHG-EVAL CUSTOM-MNU
OPS-CND MEA-CND SYS-CND CHG-TYPE NEXT-NG RE-EXAM-NG MANL-MEAS
X0~7
Y0~7
READY
MODEL0
MODEL1
Ë
When a 2 point search has been specified.
Registration number
Degree of match with the
reference image for model 0
Average gray level in the
reference image for model 0*
Detection coodinate for model 0
Degree of match with the
reference image for model 1
Average gray level in the
reference image for model 1*
Detection coodinate for model 1
Pressing the TRG/BRT key will start a measurement manually.
Final evaluation result
[Display of the inspection results]
Measuring time
Measurement program number
When you want to select a numeric calculation
- Select "RETURN" to return to the [MEAS COND] menu, and then select
"NUM-CALC" and press the SET key.
-
See "Chapter 15: Numerical Calculations"
When you want to select a PC function
- Select "RETURN" to return to the [MEAS COND] menu, and then select
"OUT-COND" and press the SET key.
-
See "Chapter 16: PC Function"
Return to the [MEAS COND] menu.
Description
Obtain average light level of the image in the area detected using the gray search.
Calculate the difference of the absolute values from the image detected using the
gray search and the reference image. The result is light level difference. By
obtaining this value, you can get an idea of the total change in light level.
Total light level difference =
Σ
(Ni — Nt)
Ni : Light level of the captured image (contraction 3)
Nt : Light level of the reference image (contraction 3)
Average
light level
Difference
absolute
value
* Average light level or difference in absolute value
To select these items, use lines "
4
MATCHING" on the "MEAS COND" menu.
-
page 5-2.