5-2
Degree of Match Inspection
5
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
S S × × × × × × × × × × × × × ×
× S × × × × × × × × × × × × × ×
○ ○ × × × × × × × × × × × × × ×
1. Enter a registration number (0 to 15), and
select a mode (1-point search or 2-point
search).
2. Move the cursor to "S" (gray search
condition) and press the SET key
.
To measure the distance and angle,
select this item and press the SET key.
-
Chapter 14
1. Select "MEAS COND (mesurement
conditions)."
When "MEASUREMENT 1" is selected.
Æ
Example of setting (display) of mode and numerical calculation
Registration No.
5
Model 0
6
Model 1
Numeric calculation
X : No setting
Registration No.1: 2-point search, numerical calculation result No.01:
Performed
Registration No.0: 1-point search, numerical calculation result No.00:
Performed
Move the cursor to "S" (gray search condition) and press the SET key.
To the next page
COMPARE-IMGS
-
pages 3-23 to 3-25
-
Page 3-14
-
Page 3-10
-
Page 3-7
[TYPE MEAS COND]
[MEASUREMENT1]
6
MEASUREMENT 1
CHK-DEG-MATCH C1
(MEAS-COND)
OPS-MENU RETURN LOCK
[TYPE MEAS COND]
[MEAS COND]
6
MEASUREMENT 1 CHK-DEG-MATCH C1
(MEAS-COND)
1
DTECT PRECISION
STANDARD HIGH
2
REGISTER NO.
00(0~15) NO 1P-SCH 2P-SCH
3
SEARCH
YES NO
4
MATCHING
AVG-GRAY DIFF.ABS
REGISTER NO.
5
MDL0
6
MDL1
NUMERIC CALC
OPS-MENU RETURN LOCK EVALUATION DST&ANG NUM-CALC OUT-COND
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
1
MEAS SELECTION
NO POSI-DEVIATION CHK-DEG-MATCH
INSPECT-LEAD INSPECT-BGA/CSP
MEAS-BIN-AREA CNT-BIN-OBJ LABEL-BIN-OBJ
POINT-MEAS MULTI-POSI MULTI-MATCHES
2
SELECT CAMERA
CAM1 CAM 2 CAMPARE-IMGS(CAM1)
3
CHNG GRAY LEBEL
NO YES(00.0TIMES
γ
+
γ
- CHNG-L INCRS-M)
4
SPACE FILTER
NO
NUM-OF-TIMES 0(0~5)
S S
S
Setting the measurement programs (page 1-10 to 11: Select "CHK-DEG-MATCH" (degree of
match inspection) on the "MEAS SELECTION" line, and press the SET key.)