1-4
Setting and Operating Outline
1
1-3 Screen specifications
[1] Operation (run) screen
After selecting the "STANDARD MENU" and save it (see page 1-2), supply power to the controller (IV-
S31M/S32M/S33M), and the MAIN OPS MENU (startup screen) will be displayed on the monitor.
- Before applying the power, make sure that the power cable, monitor cable, camera cables, and
remote key pad have been connected to the controller.
2
The results of the programmable output (auxiliary relay C116) are displayed.
If C116 has not been set, the results of C112 are output.
-
See page 16-8
3
T C1 L
æ
Display
OK
NG
"OK" is displayed when all of the individual evaluation results are acceptable.
"NG" is displayed if any single evaluation result is unacceptable.
(Error
message)
Description
4
LOCK FULL VX.X
Ë
5
C1= 002.2 OK
- This item is displayed when the light level monitor "MNTR LIGHT LVL" on the
[OBJECT TYPE SYS.] menu has been set to "YES."
-
See page 3-31
6
Measurement No. (0 to 4), camera No. (1 or 2) and measurement program name
Average light level and judgment result (OK/NG)
Camera No. (C1 = camera 1, C2 = camera 2)
Flashes during communications
System program version number
Image capture modes (Fixed "FULL" for the IV-S31M/S32M):
FULL = full, HALF = half, F+H = Full + half.
Run menu is locked ("LOCK" is not displayed when the screen is unlocked.)
An error code and the measurement number that caused the error are
displayed on the upper line. The error message is displayed on the lower line.
Operation status display:
○
flashing = running,
Image brightness: H = Original brightness of captured image
L = Brightness reduced to half that in the captured image
Output monitor status: C1 = Camera 1, C2 = Camera 2, C1/C2 = Camera 1 & 2
NG = NG image, C1/NG = Camera 1 & NG image
Image display mode: F = Freeze mode, T = Through mode (raw images),
N = No camera input (To change between F and T
modes, press the SEL key.)
(1) MAIN OPS MENU screen
- To display a dynamic image on the MAIN OPS MENU, set the through image function to "Yes."
-
See page 2-10.
T.IMG C1 L
LOCK FULL VX.X
C1=002.2 OK
C2=100.0 OK
NG IMG 0(X)
(TYPE00)AREA1
OK
MEAS XXXXms 2000-08-01 10:30
MEASURE 0 CAM1 POSI-DEVIATION
CHG-MEA CHG-REG CHG-RST CHG-C1 CHG-C2 CHG-EVAL CUSTOM-MNU
OPS-CND MEA-CND SYS-CND CHG-TYPE NG-IMG-DSP NEXT-NG MANL-MEAS
X0~7
Y0~7
READY
Display measurment
result for each
measurement
program
1
2
8
9
7
3
4
5
0
6
1
Object type No. ((IV-S33M: 00 to 63, IV-S32M: 00 to 31, IV-S31M: 00 to 15) and the name assigned by
the user for each object type.