12-2
Multiple position measurement
12
[TYPE MEAS COND]
[MEASUREMENT1]
6
MEASUREMENT 1 MULTI-POSI C1 (MEAS-COND)
1
MEAS SELECTION
NO POSI-DEVIATION CHK-DEG-MATCH
INSPECT-LEAD INSPECT-BGA/CSP
MEAS-BIN-AREA CNT-BIN-OBJ LABEL-BIN-OBJ
POINT-MEAS MULTI-POSI MULTI-MATCHES
2
SELECT CAMERA
CAM1 CAM 2 CAMPARE-IMGS(CAM1)
3
CHNG GRAY LEBEL
NO YES(00.0TIMES
γ
+
γ
- CHNG-L INCRS-M)
4
SPACE FILTER
NO
NUM-OF-TIMES 0(0~5)
OPS-MENU RETURN LOCK
[TYPE MEAS COND]
[MEAS COND]
6
MEASUREMENT 1 MULTI-POSI C1 (MEAS-COND)
1
DTECT PRECISION
STANDARD HIGH
2
REGISTER NO.
0(0~3) NO GRAY-SRC EDGE DTECT
3
DETECT ORDER
SCAN-ORDER MATCH
REGISTER NO.
4
DTECT OBJECT
NUMERIC CALC
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
S E × ×
00 01 02 03 04 05
S E × ×
○ ○ × × × ×
REGISTER NO.
4
DTECT OBJECT
NUMERIC CALC
Setting the measurement program (Page 1-10 to 1-11: Select "MULTI-POSI" on the "MEAS SELECTION"
line and press the SET key).
1. Select MEAS COND (measurement
conditions) and press the SET key.
When "MEASUREMENT 1" is selected.
COMPARE-IMGS
-
Page 3-23 to 25.
-
Page 3-14
-
Page 3-10
-
Page 3-7
1. Pick a register number (0 to 3) and
then select either "GRAY-SRC" or
"EDGE DTECT."
2. When "gray search" is selected, set
the detection order for either "SCAN-
ORDER" or "MATCH."
3. Select S (gray search) or E (edge
detection)and press the SET key.
To measure the distance and angle,
select this item and press the SET key.
-
Chapter 14
»
Setting example for target detection and numerical calculation
When "GRAY-SRC" is selected on line
"
2
REGISTER NO", "S" will be
displayed. When "EDGE DTECT" is
selected, "E" is displayed here.
When the calculation result is set to
"YES," (page 15-8), a circle will be
displayed.
OPS-MENU RETURN LOCK EVALUATION DST&ANGL NUM-CALC OUT-COND
When S (gray search) is selected
When E (edge detection)
is selected
To the next page
Page 12-4
"X" means no setting