4-5
Positional Deviation Measurement
4
Continued from page 4-3 or previous page
You can set the output destinations
using the up and down keys.
(No, Y0 to Y7, C000 to C127)
Displayed only when one of the
measurements 1 to 4 has been
selected.
-Items
9
to
e
are displayed in the 2P-SCH (2-point search), 2P-EDGE (2-point edge) and 1P-
SCH + 1P-EDGE (1-point 1-point edge) modes.
- Lines
7
and
e
are displayed as follows when edge detection is selected.
-
Page 3-16
[EVALUATION COND]
1
REGISTER NO. 0(0~7)
[TEST RESULT]
[OUTPUT]
2
CONDITION SET RESET
AUTO(+10%)
3
X COORD.(MDL0) 000.0~511.0
X0= 000.0
OK
NO
4
Y COORD.(MDL0) 000.0~479.0
Y0= 000.0
OK
NO
5
x DEVIATE(MDL0) -511.0~+511.0
x0=+000.0
OK
NO
6
y DEVIATE(MDL0) -479.0~+479.0
y0=+000.0
OK
NO
7
MATCH LVL(MDL0) -10000~+10000
M0=+09000
OK
NO
8
ANGULAR DEVIATE -180.0~+180.0
B0=+010.0
OK
NO
9
X COORD.(MDL1) 000.0~511.0
X1= 000.0
OK
NO
0
Y COORD.(MDL1) 000.0~479.0
Y1= 000.0
OK
NO
q
x DEVIATE(MDL1) -511.0~+511.0
x0=+000.0
OK
NO
w
y DEVIATE(MDL1) -479.0~+479.0
y0=+000.0
OK
NO
e
MATCH LVL(MDL1) -10000~+10000
M1=+09000
OK
NO
r
TEST
EXEC(WITH-POSI.WITHOUT-POSI.ADJ)
OPS-MENU RETURN LOCK
When you want to select a numeric calculation
- Select "RETURN" to return to the [MEAS COND] menu, and then select
"NUM-CALC" and press the SET key.
-
See "Chapter 15: Numerical Calculations"
When you want to select a PC function
- Select "RETURN" to return to the [MEAS COND] menu, and then select
"OUT-COND" and press the SET key.
-
See "Chapter 16: PC Function"
Ë
When a 2 point search has been specified.
The displays for other modes are shown in the next page.
F.IMG C1 L
VX.X
(TYPE00)
OK
MEAS XXXXms 1999-08-01 10:30
MEASURE 0 CAM1 POSI-DEVIATION
REGISTER NO(0~7)
X0=176.0
OK
Y0=322.0
OK
x0=+000.0
OK
y0=+000.0
OK
M0=+10000 OK
B0=+001.7
OK
X1=534.0
OK
Y1=480.0
OK
x1=+001.0
OK
y1=+001.0
OK
M1=+09999 OK
Amount of angular deviation
Degree of match with the
reference image for model 1
Registration number
Degree of match with the
reference image for model 0
Detection coordinates in the
reference image for model 0
Amount of deviation from
the reference image for model 0
Detection coordinates in the
reference image for model 1
Amount of deviation from
the reference image for model 1
X0~7
Y0~7
READY
Model 0
Model 1
Pressing the TRG/BRT key will start a measurement manually.
Final evaluation result
[Display of the measured
results]
Measuring time
Measurement program number
CHG-MEA CHG-REG CHG-RST CHG-C1 CHG-C2 CHG-EVAL CUSTOM-MNU
OPS-CND MEA-CND SYS-CND CHG-TYPE NEXT-NG RE-EXAM-NG MANL-MEAS
Return to the [MEAS COND] menu.
7
SEARCH EDGE(MDL0) YES NO K0 ---- When "1P-EDGE " or "2P-EDGE" is selected.
e
SEARCH EDGE(MDL1) YES NO K0 ---- When "2P-EDGE" or "1P-SCH + 1P-EDGE" is selected.