13-2
Multiple degree of match inspection
13
[TYPE MEAS COND]
[MEASUREMENT1]
6
MEASUREMENT 1 MULTI MATCHES C1 (MEAS-COND)
OPS-MENU RETURN LOCK
[TYPE MEAS COND]
[MEAS COND]
6
MEASUREMENT 1 MULTI MATCHES C1 (MEAS-COND)
1
DTECT PRECISION
STANDARD
HIGH
2
REGISTER NO.
0(0~3) NO YES
3
MATCHING
AVG-GRAYS DIFF.ABS
4
DETECT ORDER
SCAN-ORDER MATCH
REGISTER NO.
5
DTECT OBJECT
NUMERIC CALC
OPS-MENU RETURN LOCK EVALUATION DST&ANGL NUM-CALC OUT-CON
D
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
S S
00 01 02 03 04 05
S S × ×
○ × × × × ×
1
MEAS SELECTION
NO POSI-DEVIATION CHK-DEG-MATCH
INSPECT-LEAD INSPECT-BGA/CSP
MEAS-BIN-AREA CNT-BIN-OBJ LABEL-BIN-OBJ
POINT-MEAS MULTI-POSI MULTI-MATCHES
2
SELECT CAMERA
CAM1 CAM 2 CAMPARE-IMGS(CAM1)
3
CHNG GRAY LEBEL
NO YES(00.0TIMES
γ
+
γ
- CHNG-L INCRS-M)
4
SPACE FILTER
NO
NUM-OF-TIMES 0(0~5)
REGISTER NO.
5
DTECT OBJECT
NUMERIC CALC
»
Setting example for target detection and numerical calculation
Setting the measurement program (Page 1-10 to 1-11: Select "MULTI-MATCHES" on the "MEAS
SELECTION" line and press the SET key).
1. Select MEAS COND (measurement
conditions) and press the SET key.
When "MEASUREMENT 1" is selected.
COMPARE-IMGS
-
Page 3-23 to 25.
-
Page 3-14
-
Page 3-10
-
Page 3-7
1. Pick a register number (0 to 3) and
then select either "NO" or "YES."
2. Set the gray level (G) to detect in the
image.
-
Page 13-4.
3. Select "SCAN-ORDER" or "MATCH."
4. Select S (gray search) for an object to
detect and press the SET key.
To measure the distance and angle,
select this item and press the SET key.
-
Chapter 14
When "YES" is selected on line "
2
REGISTER NO.", "S" will be displayed.
When the calculation result is set to
"YES," (page 15-9), a circle will be
displayed.
When S (gray search) is selected and press the SET key
To the next page
"X" means no setting