Setting the Conditions for Each Object Type
3-27
3
(2) Operation setting details
Setting takes place on the [POSITION CORRECT] menu.
Ë
Ë
Ë
Ë
Ë
Setting procedure
1. Move the cursor to "NO" on the right of the (MEAS-COND) item.
-
The [POSITION CORRECT] menu will appear in the lower window.
2. Move the cursor to "
1
MODE" using the up and down keys and press the SET key.
3. Select the mode number in "
1
MODE" line as "0."
4. Move the cursor to "XY-ADJ." or "ANGLE-ADJ.(STANDARD HIGH)" or "NO" using the left and
right keys. Then press the SET key.
-
The "NO" column on "MEASURE0 CAM1/2" line in the upper window will change to "YES."
- When "XY-ADJ." is selected, lines
2
and
3
will be displayed.
- When ANGLE-ADJ. (STANDARD HIGH) is selected, lines
2
,
3
and
4
will be displayed.
5. Select line "
2
X CORRECTION," using the up and down keys.
- When no X correction is needed, select "NO" using the left and right keys.
- When an X correction is needed, select the register number (0 to 7) and the model number (1 or
2) for measurement 0 (position deviation measurement: camera 1/2) using the left/right and up/
down keys. Press the SET key to confirm your choice.
6. Set the "
3
Y CORRECTION" and "
4
ADJUST ANGLE" line the same as described in step 5
above.
7. Select line "
1
MODE," using the up and down keys. Then press the SET key. Then set the mode
number to "1," using the up and down keys.
8. Set the choices the same as described in steps 4 to 6 above.
When "ANGLE-ADJ (STANDARD HIGH)" is selected for mode 0, the "ANGLE-ADJ. (STANDARD
HIGH)" choice will not be displayed for mode 1.
Ë
Ë
Ë
Ë
Ë
Order of position correction
On the [TYPE MEAS COND] menu, move the cursor to
4
or
5
and press the SET key.
2
4
3
1
5
[TYPE MEAS COND]
[POSITION CORRECT]
1
OBJECT TYPE NO.
00(0~63) NO YES
2
SELECT CAMERA
CAM1&2 CAM1&NG-IMG
3
IMG PRE-PROCESS
(TO NEXT SUB-MENU)
4
MEASURE 0 CAM1 POSI-DEVIATION
(MEAS-COND) NO
5
MEASURE 0 CAM2 POSI-DEVIATION
(MEAS-COND) NO
1
MODE
0(0~1)NO XY-ADJ. ANGLE-ADJ.(STANDARD HIGH)
2
X CORRECTION
NO REG0(0~7) MDL0
3
Y CORRECTION
NO REG0(0~7) MDL0
4
ADJUST ANGL
NO REG0(0~7) MDL0
OPS-MENU RETURN LOCK
Mode 0
Mode 1
No
XY ADJ.
- X CORRECTION (no/yes)
- Y CORRECTION (no/yes)
ANGLE ADJ. (STANDARD HIGH)
- X CORRECTION (no/yes)
- Y CORRECTION (no/yes)
- ADJUST ANGL (no/yes)
No
XY ADJ.
- X CORRECTION (no/yes)
- Y CORRECTION (no/yes)
ANGLE ADJ. (STANDARD HIGH)
- X CORRECTION (no/yes)
- Y CORRECTION (no/yes)
- ADJUST ANGL (no/yes)