Ex
䠅
UV lamp illumination time is set in 5 minutes;
Procedures
MENU
key
0
In Top Screen, press MENU key and select “Tools”.
Tools
1
Press ENTER key and select “UV Setting” column in “Select Tools (1/2)” display.
2
Press MENU key and select “OK”.
OK
3
Press ENTER key and input “5” in the right side of “UV Timer” in “UV Setting” display.
4
Press MENU key and select “OK”.
OK
5
Press ENTER key and “Select Tools (1/2)” display is appeared.
<UV lamp accumulation time>
㻌 㻌 㻌 㻌
Display range of UV lamp accumulation time is 0~260%.
Note) UV lamp accumulation time is displayed by percentage. 1000Hours = 100%
<UV lamp 24hours illumination mode>
Chamber wall will be sterilized by UV lamp in this mode.
When you input “0” in the right side of “UV 24h Mode” column in “UV Setting” display, UV lamp 24hours illumination
mode is inactive.
When you input “1” in the right side of “UV 24h Mode” column in “UV Setting” display, UV lamp 24hours illumination
mode is active.
Note) If you open an door during UV lamp 24hours illumination mode, UV lamp 24hours illumination mode will be
forcibly inactive on the way.
The detection for UV lamp malfunction will not be done during UV lamp 24hours illumination mode.
㻌 㻌 㻌 㻌
Ex) When you set UV lamp 24hours illumination mode;
Procedures
MENU
key
0
In Top Screen, press MENU key and select “Tools”.
Tools
1
Press ENTER key and select “UV Setting” column in “Select Tools (1/2)” display.
2
Press MENU key and select “OK”.
OK
3
Press ENTER key and input “1” in the right side of “UV 24h Mode” in “UV Setting”
display.
4
Press MENU key and select “OK”.
OK
5
Press ENTER key and “Select Tools (1/2)” display is appeared.
(UV lamp relay will be active and UV lamp will illuminate)
Summary of Contents for MCO-19M
Page 7: ... 4 Dimensions Power cord ...
Page 16: ...Wiring diagram 13 ...
Page 17: ...Circuit diagram Main PCB 14 ...
Page 18: ... LCD PCB 15 ...
Page 110: ...MCO 19M UVH MCO 19M UV MCO 19M Multi Gas Incubator INSTRUCTION MANUAL 107 ...
Page 112: ...CONTENTS SPECIFICATIONS P 74 PERFORMANCE P 75 SAFETY CHECK SHEET P 76 109 2 ...
Page 183: ...Fig A Stacking plate B Stacking plate A Protective sticker Front panel Hook Front 180 73 ...
Page 187: ...SANYO Electric Co Ltd Printed in Japan DC3186 150B ...