2-4
Installation
CSD7 Servo Drive (EtherCAT)
When installing several drives, you must the following criteria.
•
Basically, keep 10 mm distance between products.
•
In case of zero stacking installation, attach an external fan to keep
the ambient temperature of the products below 40 degrees
Celsius.
30.0 mm
(1.18 in.)
Adjacent Wall
Top of Drive
100 mm
Bottom of Drive
50.0 mm(1.97 in.)
< Installation by 10mm intervals >
30.0 mm
(1.18 in.)
Adjacent Wall
Top of Drive
100 mm
Bottom of Drive
50.0 mm(1.97 in.)
< Installation by Zero Stacking >