Object Dictionary
7-29
CSD7 Servo Drive (EtherCAT)
larger than the setups (level of gain control
switching and hysteresis of control switching).
5
2nd gain selection when the positional deviation is
larger than the setups (level of gain control
switching and hysteresis of control switching).
Position Error
6
2nd gain selection when more than one command
pulse exists between 200usec.
Position Command
7
2nd gain selection when the positional deviation
counter value exceeds the setup of Positioning
completer range.
In-Position
8
2nd gain selection when the motor actual speed
exceeds the setup.
Velocity
9
2nd gain selection when no position commands
applied and the motor actual speed falls slower
than the setup.
Position command
and Velocity
Sub-Index 4
Ft-0.06[D3]
Absolute Position Transmission Type
RSWare : Drive - Encoders - Absolute Feedback Transfer Type
Range
Value Description
Name in RSWare
0
Same as Command Polarity
Same as Command
Polarity
1
Always CCW
Always CCW
2
Always CW
Always CW
0x2007
Servo Drive ID
ALL
Setting Range
Size (Data Type)
Unit
Access
PDO Map
Attribute
Init Value
Ft-no
0~247
1 byte(USINT)
-
RW
-
Always
1
Ft-0.07
It indicates the ID of the servo drive.
0x200A
1st Assignment for Sequence Input Signal
ALL
Sub-Index 0
Number of Entries
Setting Range
Size (Data Type)
Unit
Access
PDO Map
Attribute
Init Value
Ft-no
-
2 byte(UINT)
-
RO
-
-
4
Ft-0.10
Sub-Index 1
Servo-ON Enable Signal (/ENABLE)
Setting Range
Size (Data Type)
Unit
Access
PDO Map
Attribute
Init Value
Ft-no
0x0~0xb
1 byte(USINT)
-
RW
-
Servo Off
0xb
Ft-0.10[D0]
Sub-Index 2
Positive Over-travel (P-OT)
Setting Range
Size (Data Type)
Unit
Access
PDO Map
Attribute
Init Value
Ft-no
0x0~0xb
1 byte(USINT)
-
RW
-
Servo Off
0x2
Ft-0.10[D1]
Sub-Index 3
Negative Over-travel (N-OT)
Setting Range
Size (Data Type)
Unit
Access
PDO Map
Attribute
Init Value
Ft-no
0x0~0xb
1 byte(USINT)
-
RW
-
Servo Off
0x3
Ft-0.10[D2]
Sub-Index 4
P Control (/P-CON)
Summary of Contents for OEMax CSD7
Page 1: ...CSD7 Servo Drive User Manual Catalog Number s CSD7_ BN F 1 EtherCAT Network type ...
Page 4: ......
Page 12: ...viii CSD7 Servo Drive EtherCAT SAFETY FUNCTION CONNECTOR B 6 ...
Page 23: ...Preface P 11 CSD7 Servo Drive EtherCAT ...
Page 24: ......
Page 33: ...Installation 2 5 CSD7 Servo Drive EtherCAT 100W 200W 400W 800W 1KW 1 5KW ...
Page 38: ......
Page 76: ......
Page 94: ......
Page 114: ......
Page 126: ......
Page 314: ......
Page 327: ...able and Connector Specification B 5 CSD7 Servo Drive EtherCAT ...
Page 330: ......
Page 331: ...Publication CSD7 UM001A Network EN October 2015 ...
Page 332: ...Copyright 2015 RS Automation Co Ltd All rights reserved ...