Application
9-31
CSD7 Servo Drive (EtherCAT)
•
Servo Fault
When the voltage of encoder inside is detected about 2.7 [V] or less, the battery low
voltage fault for absolute encoder occurs. At this time, the servo drive stops the operation.
When ‘Battery low voltage fault for absolute encoder’ occurs, the saved information on
encoder may be damaged.
In case of the Q type 17-bit absolute encoder, when an absolute encoder
batter low battery warning occurs, the warning is reset only by running the
fault reset (run-08). At this time, both multi-turn and single-turn data are
reset.
Connecting Battery to Encoder
The below figure is how to connect the battery to encoder of servo motor.
1.
Prepare the proper battery for specification.
2.
Be careful of the polarity when battery is connected.
Battery
Connection to Battery
Note
Summary of Contents for OEMax CSD7