Application
9-19
CSD7 Servo Drive (EtherCAT)
Definition of S Curve Operation
As shown in the below figure, by performing the S-curve command at the conversion point
of acceleration/deceleration, more smooth operation can be had.
S-curve Time Setting
Set the S-curve time on the below parameter.
0x2208
S-Curve Time
CSP
Setting Range
Size (Data Type)
Unit
Access
PDO Map
Attribute
Init Value
Ft-no
0~5000
2 byte(UINT)
msec
RW
-
Always
0
Ft-2.08
Ft-2.08
S-Curve Time
Description
It set the S-curve time in each acceleration and deceleration.
Velocity Command
Actual Vlocity
Actual Vlocity
Time
<Velocity Command>
<Acc/Dec Time Setting>
Rated Speed of Motor
Setting Speed of Motor
Rated Speed of Motor
Setting Speed of Motor
Rated Speed of Motor
Setting Speed of Motor
<S-curve Acc/Dec Time Setting>
Time
Time
S-curve Time Setting