7-26
Object Dictionary
CSD7 Servo Drive (EtherCAT)
0~1
1 byte(USINT)
-
RW
-
Servo Off
0x0
Ft-0.02[D3]
Sub-Index 1
Ft-0.02[D0]
Selection of DB Stop Method
RSWare : Drive - Stopping Functions - Fault and Disable Braking
Range
Value Description
Name in RSWare
0
Keep DB after DB stop
Brake and hold
1
DB is released after DB stop.
Brake and release
2
Stop Free run (operation) without DB stop
Free Stop
3
Keep DB after stop Free run
Free Stop and hold
Sub-Index 2
Ft-0.02[D1]
Selection of Over Travel stop method
RSWare : Drive - Stopping Functions - Over Travel Stop Method
Range
Value Description
Name in RSWare
0
Stop by normal torque contorl during overtravel.
At this monent,can contorl torque by setting
overtravel torque linit [Ft-4.11].
Current Control
1
Stop by the method specified at the DB stop
method selection in [Ft-0.02][D0] when overtravel
occurs.
Dynamic Brake
2
No Action
No Action
Sub-Index 3
Ft-0.02[D2]
Selection of Rotation Direction for External Command
RSWare : Drive - Command Polarity
Range
Value Description
Name in RSWare
0
The command signal is not inverted so that a
positive command value results in CW Rotation,
(as viewed from shaft end).
None
1
The command signal is inverted so that a positive
command value results in CCW Rotation, (as
viewed from shaft end).
Inverted
Sub-Index 4
Ft-0.02[D3]
AC Line Open-phase Detection
RSWare : Drive - AC Line Loss Check
Range
Value Description
Name in RSWare
0
Check input power
100W~400W : Enable single-phase open check
800W~1.5kW : 3-phase open check
Enable
1
Do not check the input power
Disable
2
Single-phase input
Single phase input
0x2003
Selection of Auto Tuning Function
CSP
Sub-Index 0
Number of Entries
Setting Range
Size (Data Type)
Unit
Access
PDO Map
Attribute
Init Value
Ft-no
-
2 byte(UINT)
-
RO
-
-
4
Ft-0.03
Sub-Index 1
Off-line Tuning Mode Setting
Setting Range
Size (Data Type)
Unit
Access
PDO Map
Attribute
Init Value
Ft-no
Summary of Contents for OEMax CSD7
Page 1: ...CSD7 Servo Drive User Manual Catalog Number s CSD7_ BN F 1 EtherCAT Network type ...
Page 4: ......
Page 12: ...viii CSD7 Servo Drive EtherCAT SAFETY FUNCTION CONNECTOR B 6 ...
Page 23: ...Preface P 11 CSD7 Servo Drive EtherCAT ...
Page 24: ......
Page 33: ...Installation 2 5 CSD7 Servo Drive EtherCAT 100W 200W 400W 800W 1KW 1 5KW ...
Page 38: ......
Page 76: ......
Page 94: ......
Page 114: ......
Page 126: ......
Page 314: ......
Page 327: ...able and Connector Specification B 5 CSD7 Servo Drive EtherCAT ...
Page 330: ......
Page 331: ...Publication CSD7 UM001A Network EN October 2015 ...
Page 332: ...Copyright 2015 RS Automation Co Ltd All rights reserved ...