7-58
Object Dictionary
CSD7 Servo Drive (EtherCAT)
Setting Range
Size (Data Type)
Unit
Access
PDO Map
Attribute
Init Value
Ft-no
0~60
2 byte(UINT)
sec
RW
-
Servo off
10
Ft-4.23
▶
RSWare : Drive - RMS Current Load Factor Function - RMS Current Load Factor
Cumulative Time Setting
▶
It set the time window size to calculate the Average Torque Load Factor and Maximum
Torque Load Factor.
0x2418
Threshold Value 1 for Average Torque Load Factor
ALL
Setting Range
Size (Data Type)
Unit
Access
PDO Map
Attribute
Init Value
Ft-no
0~350
4 byte(UDINT)
%
RW
-
Servo off
350
Ft-4.24
▶
RSWare : Drive - RMS Current Load Factor Function - RMS Current Load Factor
Threshold Setting 1
▶
It set the threshold value 1 of average torque load factor.
0x2419
Threshold Value 2 for Average Torque Load Factor
ALL
Setting Range
Size (Data Type)
Unit
Access
PDO Map
Attribute
Init Value
Ft-no
0~350
4 byte(UDINT)
%
RW
-
Servo off
350
Ft-4.25
▶
RSWare : Drive - RMS Current Load Factor Function - RMS Current Load Factor
Threshold Setting 2
▶
It set the threshold value 2 of average torque load factor.
Summary of Contents for OEMax CSD7
Page 1: ...CSD7 Servo Drive User Manual Catalog Number s CSD7_ BN F 1 EtherCAT Network type ...
Page 4: ......
Page 12: ...viii CSD7 Servo Drive EtherCAT SAFETY FUNCTION CONNECTOR B 6 ...
Page 23: ...Preface P 11 CSD7 Servo Drive EtherCAT ...
Page 24: ......
Page 33: ...Installation 2 5 CSD7 Servo Drive EtherCAT 100W 200W 400W 800W 1KW 1 5KW ...
Page 38: ......
Page 76: ......
Page 94: ......
Page 114: ......
Page 126: ......
Page 314: ......
Page 327: ...able and Connector Specification B 5 CSD7 Servo Drive EtherCAT ...
Page 330: ......
Page 331: ...Publication CSD7 UM001A Network EN October 2015 ...
Page 332: ...Copyright 2015 RS Automation Co Ltd All rights reserved ...