SMIQ
Digital Standard DECT
1125.5555.03
2.325
E-9
(TRIGGER...)
EXT TRIGGER
DELAY
Setting the number of symbols by which an external
trigger signal is delayed before it starts the DECT
signal generation.
This is used for setting the time synchronization
between the SMIQ and the DUT.
IEC/IEEE-bus
:SOUR:DECT:TRIG:DEL 3
EXT RETRIGGER
INHIBIT
Setting the number of symbols for which a restart is
inhibited after a trigger event.
With TRIGGER MODE RETRIG selected, each new
trigger signal restarts the DECT signal generation.
This restart can be inhibited for the entered number
of symbols.
Example:
The entry of 1000 symbols causes new trigger
signals to be ignored for the duration of 1000 sym-
bols after a trigger event
IEC/IEEE-bus
:
SOUR:DECT:TRIG:INH 1000
TRIGGER OUT2
DELAY
Input value of delay of trigger signal at TRIGOUT 2
output compared with beginning of frame.
IEC/IEEE-bus :
SOUR:DECT:TRIG:OUTP:DEL 2
TRIGGER OUT2
PERIOD
Input value of output signal period at TRIGOUT 2
output given in frames.
IEC/IEEE-bus :
SOUR:DECT:TRIG:OUTP:PER 1