Digital Standard PHS
SMIQ
1125.5555.03
E-9
2.122
(TRIGGER...)
EXT TRIGGER
DELAY
Setting the number of symbols by which an external
trigger signal is delayed before it starts the PHS
signal generation.
This is used for setting the time synchronization
between the the SMIQ and the DUT.
IEC/IEEE-bus command
:SOUR:PHS:TRIG:DEL 3
EXT RETRIGGER
INHIBIT
Setting the number of symbols for which a restart is
inhibited after a trigger event.
With TRIGGER MODE RETRIG selected, each new
trigger signal restarts the PHS signal generation. This
restart can be inhibited for the entered number of
symbols.
Example:
The entry of 1000 symbols causes new trigger
signals to be ignored for the duration of 1000 sym-
bols after a trigger event
IEC/IEEE-bus
:SOUR:PHS:TRIG:INH 1000
TRIGGER OUT 2
DELAY
Input value of delay of trigger signal at TRIGOUT 2
output compared with beginning of frame.
IEC/IEEE-bus
:SOUR:PHS:TRIG:OUTP:DEL 2
TRIGGER OUT2
PERIOD
Input value of output signal period at TRIGOUT 2
output given in frames.
IEC/IEEE-bus
:SOUR:PHS:TRIG:OUTP:PER 1