Digital Standard PHS
SMIQ
1125.5555.03
E-9
2.120
(MODULATION...)
SET TO
STANDARD
Sets the subsequent modulation parameters to the
values predefined by the standard.
MODULATION TYPE
Displays the modulation type.
SYMBOL RATE
Input value for the symbol rate. 192 ksymbol/s are
preset.
IEC/IEEE-bus
:SOUR:PHS:SRAT 192.01 KHZ
FILTER
Selection of baseband filter. A selection between
Nyquist filters COS, SQRCOS and a user-defined filter
USER (cf. Section Digital Modulation) is possible.
IEC/IEEE-bus
:SOUR:PHS:FILT:TYPE COS
ROLL OFF FACTOR
Input value for the roll-off factor.
IEC/IEEE-bus
SOUR:PHS:FILT:PAR 0.50
FILTER MODE
Selection of filter mode.
LOW_ACP
Filter for minimum Adjacent Channel
Power.
IEC
:SOUR:PHS:FILT:MODE LACP
LOW_EVM Filter for minimum vector error.
IEC
:SOUR:PHS:FILT:MODE LEVM
TRIGGER MODE...
Opens a window for selecting the trigger mode.
AUTO
The PHS signals are continuously transmitted in the
activated slots.
IEC/IEEE-bus command
:SOUR:PHS:SEQ AUTO
RETRIG
The PHS signals are continuously transmitted in the
activated slots. A trigger event causes a restart.
IEC/IEEE-bus command
:SOUR:PHS:SEQ RETR
ARMED_AUTO
The PHS signal generation does not start until a trigger
event has occurred. The unit then automatically
switches over to the AUTO mode and can no longer be
triggered.
IEC/IEEE-bus command
:SOUR:PHS:SEQ AAUT
ARMED_RETRIG
The PHS signal generation does not start until a trigger
event has occurred. The unit then automatically
switches over to the RETRIG mode. Each new trigger
event causes a restart.
IEC/IEEE-bus command
:SOUR:PHS:SEQ ARET
EXECUTE
TRIGGER
Executes a trigger even to start the PHS signal generation.
IEC/IEEE-bus command
:TRIG:DM:IMM
TRIGGER...
Opens a window for selecting the trigger source, for configuring the trigger