SMIQ
Digital Standard 3GPP W-CDMA (FDD)
1125.5555.03
E-9
2.181
Test1_64
TEST MODEL 1 (64 channels)
Spectrum emission mask
ACLR
Spurious emissions
Transmit intermodulation
Modulation accuracy
Test2
TEST MODEL 2
Output power dynamics
Test3_16
TEST MODEL 3 (16 channels)
Peak code domain error
Test3_32
TEST MODEL 3 (32 channels)
Peak code domain error
IEC/IEEE-bus command
:SOUR:W3GP:SETT:TMOD
"TEST1_16"
No test models are defined for the uplink in the 3GPP standard. To be able to
generate appropriate test signals by a keystroke nevertheless, the SMIQ offers
predefined test signals also for the uplink.
Test model
Description
C+D60 k
Mobile station 1 is activated in the
DPCCH + DPDCH mode. 60 ksps is
selected as overall symbol rate and
the power of DPCCH and DPDCH is
set to 0 dB.
TEST MODELS (NOT
STANDARDIZED)
C+D960 k
Mobile station 1 is activated in the
DPCCH + DPDCH mode. 960 ksps is
selected as overall symbol rate and
the power of DPCCH and DPDCH is
set to 0 dB.
IEC/IEEE bus
:SOUR:W3GP:SETT:TMOD "C+D60 k"