RIGOL
Chapter 2 Front Panel Operations
2-30
DL3000 User’s Guide
CAUTION
When the fan stops working, the channel is disabled. Then, a
message is displayed, "Fan stops running!"
6.
View waveform display
After you enter the main interface, press the waveform display key
to
enter the waveform display interface, as shown in Figure 2-21. After the load
current stays at Level A for a specified time (reach the set width), the trigger is
disabled automatically. Then, the current automatically switches to Level B. For
detailed operations, refer to the descriptions in "Waveform Display
Function" section. Press the waveform display key
again to exit the
waveform display interface and return to the main interface of Pul mode.
Figure 2-21 Waveform Display Interface of Pul Mode
7.
Save and read files
In the guide interface and main interface of Pul mode, you can press Save to
save the parameters for Pul mode to the internal or external memory, and you
can read and recall it if necessary by pressing Read.
(1)
Save
After you complete the parameter setting, press Save to enter the storage
and recall interface. The file is saved in ".PUL" format. For detailed saving
operation, refer to the descriptions in "Save".
(2)
Read
Press Read to enter the storage and recall interface. Recall and read the
files in ".PUL" format or the ".RSF" files beginning with "PUL_". For detailed
reading operation, refer to descriptions in "Read". The files to be recalled
and read are allowed to be edited.
How to press the Store key on the front to perform the saving and reading
WARNING
To avoid electric shock, ensure that the DUT is connected to the
input terminals of the load properly before you enable the trigger.