![background image](http://html.mh-extra.com/html/rigol/dl3000-series/dl3000-series_user-manual_1460931050.webp)
RIGOL
Chapter 2 Front Panel Operations
2-20
DL3000 User’s Guide
(2)
Enter a value by using the numeric keys. For setting methods, refer to the
descriptions in "Parameter Setting Method".
Note: The input value of A_Level should be within the set range.
Set B_Level
The sink current toggles between a high value and a low value in Con mode.
B_Level indicates a low value. The default unit for B_Level is Ampere (A).
(1)
In the guide interface, press the Up/Down arrow key to switch the
parameter focus to "B_Level".
(2)
Enter a value by using the numeric keys. For setting methods, refer to the
descriptions in "Parameter Setting Method".
Note: The set A_Level and B_Level for a specified model should be within its
specified high and low ranges for the model.
Set Slew_RIS
Sets the sink current slew rate for the positive transitions from Level B to Level A
in Con mode. The default unit for the rising slew rate is A/μs.
(1)
In the guide interface, press the Up/Down arrow key to switch the
parameter focus to "Slew_RIS".
(2)
Enter a value by using the numeric keys. For setting methods, refer to the
descriptions in "Parameter Setting Method".
Set Slew_FAL
Sets the sink current slew rate for the negative transitions from Level A to Level
B in Con mode. The default unit for the falling slew rate is A/μs.
(1)
In the guide interface, press the Up/Down arrow key to switch the
parameter focus to "Slew_FAL".
(2)
Enter a value by using the numeric keys. For setting methods, refer to the
descriptions in "Parameter Setting Method".
Set FREQ/PER
Period: The sum of time during which the sink current stays at Level A and Level
B. The unit is s or ms.
Frequency: The reciprocal of period. The unit is Hz or kHz.
(1)
In the guide interface, press the Up/Down arrow key to switch the
parameter focus to "FREQ/PER".
(2)
Enter a value by using the numeric keys. For setting methods, refer to the
descriptions in "Parameter Setting Method".
Set Width/Duty
Width: The time during which the sink current stays at Level A when it switches
to Level A in Con mode. Its unit is s or ms.
Duty: The ratio of duration of Level A to the period when the sink current
switches to Level A in Con mode.