Bit 0: Quotation priority for a destination when there is no destination of the specified type
0: Paper output priority = Priority order: 1. IP-fax destination, 2. Fax Number, 3. E-mail address, 4.
Folder
1: Electric putout order = Priority order: 1. E-mail address, 2. Folder, 3. IP-fax destination, 4. Fax
number
Bits 1 to 7: Not used
6800F1(H) - User parameter switch 33 (SWUSR_21): Not used
6800F2(H) - User parameter switch 34 (SWUSR_22)
Bit 0: Gatekeeper server used with IP-Fax 0: Disabled, 1: Enabled
Bit 1: SIP server used with IP-Fax 0: Disabled, 1: Enabled
Bits 2 to 7: Not used
6800F3(H) - User parameter switch 35 (SWUSR_23)
Redial interval when sending a backup file
6800F4(H) - User parameter switch 36 (SWUSR_24)
Maximum number of redials when sending a backup file
6800F5(H) - User parameter switch 37 (SWUSR_25)
Bit 0: Whether to stop sending a backup file if the destination folder becomes full while the machine is
sending or waiting to send a fax or the backup file. 0: No, • 1: Yes
Bit 2 and 3: Backup file is printed along with the TX communication failure report when a backup file
transmission failure occurs. 00: Do not print, 01: Print first page only, 10: Print whole file
Bit 4: Display the sender's information in the file name of documents that are forwarded to folder
destinations. 0: Disabled, 1: Enabled
Bit 5: Limit the file names of documents that are forwarded to folder destinations to plain characters only.
0: Disabled, 1: Enabled
Bit 6: When using the remote fax function, the sub-machine beeps to let you know when it has printed a
received document (If you specify "On", the machine will beep according to the setting of [Panel Key
Sound] under [System Settings].) 0: On, 1: Off
Bit 7: Not used
6800F6(H) - User parameter switch 38 (SWUSR_26)
Maximum number of transmissions the machine attempts before determining that a fax cannot be
forwarded from a sender (including special senders) to a folder destination
6800F7(H) - User parameter switch 39 (SWUSR_27)
Interval (in minutes) between resend attempts after failing to forward a fax from a sender (including
special senders) to a folder destination
6800F8(H) - User parameter switch 40 (SWUSR_28)
4. Service Tables
190
Summary of Contents for Type M12
Page 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Page 2: ......
Page 10: ...8...
Page 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Page 50: ...2 Replacement and Adjustment 48...
Page 84: ...3 Troubleshooting 82...
Page 218: ...5 Detailed Section Descriptions 216...
Page 226: ...MEMO 224 EN...