4-7
Modem setting for reception
Sets the modem type for reception. The default is "0100" (V27ter, V29, V17).
Bit 7
Bit 6
Bit 5
Bit 4
Types
0
0
0
1
V.27ter
0
0
1
0
V.27ter, V.29
0
0
1
1
V.27ter, V.29, V.33
0
1
0
0
V.27ter, V.29, V.17/V.33
Other settings - Not used
IP Fax Switch 07 (SP No. 1-111-008)
No.
Function
Comments
0
TSI information
0: Not added, 1: Added
Adds or does not add TSI information to NSS(S).
1
DCN transmission setting at T1 timeout
0: Not transmitted
1: Transmitted
Transmits or does not transmit DCN at T1 timeout.
2
Not used
Do not change this setting.
3
Hang up setting at DIS reception
disabled
0: No hang up
1: Hang up after transmitting DCN
Sets whether the machine disconnects after DIS
reception.
4
Number of times for training
0: 1 time, 1: 2 times
Selects the number of times training is done at the
same bit rate.
5
Space CSI transmission setting at no CSI
registration
0: Not transmitted
1: Transmitted
When "0" is selected, frame data is enabled.
When "1" is selected, the transmitted data is all
spaces.
6-7
Not used
Do not change these settings.
4. Service Tables
156
Summary of Contents for Type M12
Page 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Page 2: ......
Page 10: ...8...
Page 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Page 50: ...2 Replacement and Adjustment 48...
Page 84: ...3 Troubleshooting 82...
Page 218: ...5 Detailed Section Descriptions 216...
Page 226: ...MEMO 224 EN...