4
Maximum allowable frame interval during
image data reception.
0: 5 s 1: 13 s
This bit set the maximum interval between EOL
(end-of-line) signals and the maximum interval
between ECM frames from the other end.
Try using a longer setting if error code 0-21 is
frequent.
5
Not used
Do not change the settings.
6
Reconstruction time for the first line in
receive mode
0: 6 s 1: 12 s
When the sending terminal is controlled by a
computer, there may be a delay in receiving
page data after the local machine accepts set-
up data and sends CFR. This is outside the T.30
recommendation. But, if this delay occurs, set
this bit to 1 to give the sending machine more
time to send data.
Refer to error code 0-20.
ITU-T T.30 recommendation: The first line
should come within 5 s of CFR.
7
Not used
Do not change the settings.
G3-2 Switch 0B- Not used (do not change the settings)
G3-2 Switch 0C- Not used (do not change the settings)
G3-2 Switch 0E- Not used (do not change the settings)
G3-2 Switch 0F- Not used (do not change the settings)
G4 Internal Switches
The G4 internal switches (SW00 to 1F) are displayed but do not change these settings.
G4 Parameter Switches
The G4 parameter switches (SW00 to 0F) are displayed but do not change these settings.
4. Service Tables
150
Summary of Contents for Type M12
Page 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Page 2: ......
Page 10: ...8...
Page 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Page 50: ...2 Replacement and Adjustment 48...
Page 84: ...3 Troubleshooting 82...
Page 218: ...5 Detailed Section Descriptions 216...
Page 226: ...MEMO 224 EN...