Code
Meaning
Suggested Cause/Action
0-86
The line was disconnected
because the other terminal
requested a data rate using MPh
that was not available in the
currently selected symbol rate.
• The other terminal was incompatible.
• Ask the other party to contact the manufacturer.
0-87
The control channel started after
an unsuccessful primary channel.
• The receiving terminal restarted the control
channel because data reception in the primary
channel was not successful.
• This does not result in an error communication.
0-88
The line was disconnected
because PPR was transmitted/
received 9 (default) times within
the same ECM frame.
• Try using a lower data rate at the start.
• Try adjusting the cable equalizer setting.
2-11
Only one V.21 connection flag
was received
• Replace the FCU.
2-12
Modem clock irregularity
• Replace the FCU.
2-13
Modem initialization error
• Turn off the machine, then turn it back on.
• Update the modem ROM.
• Replace the FCU.
2-22
Counter overflow error of JBIG
chip
If error occurs frequently, change the settings for
resolution, paper size, compression type.
2-23
JBIG compression or
reconstruction error
Turn off the machine, then turn it back on.
2-24
JBIG ASIC error
• Turn off the machine, then turn it back on.
2-25
JBIG data reconstruction error
(BIH error)
• JBIG data error
• Check the sender’s JBIG function.
• Update the FCU ROM.
2-26
JBIG data reconstruction error
(Float marker error)
2-27
JBIG data reconstruction error
(End marker error)
2-28
JBIG data reconstruction error
(Timeout)
3. Troubleshooting
56
Summary of Contents for Type M12
Page 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Page 2: ......
Page 10: ...8...
Page 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Page 50: ...2 Replacement and Adjustment 48...
Page 84: ...3 Troubleshooting 82...
Page 218: ...5 Detailed Section Descriptions 216...
Page 226: ...MEMO 224 EN...