System Switch 18 - Not used (do not change these settings)
System Switch 19 (SP No. 1-101-026)
No
Function
Comments
0-5
Not used
Do not change the settings.
6
Extended scanner page memory
after memory option is installed
0: Disabled
1: Enabled
0: After installing the memory expansion option, the
scanner page memory is extended to 4 MB from 2
MB.
1: If this bit is set to 1 after installing the memory
expansion option, the scanner page memory is
extended to 12 MB. But the SAF memory decreases
to 18 MB.
7*
Special Original mode
0: Disabled
1: Enabled
1: If the customer frequently wishes to transmit a form
or letterhead which has a colored or printed
background, change this bit to "1". "Original 1" and
"Original 2" can be selected in addition to the "Text",
"Text/Photo" and "Photo" modes.
* This setting can be used for the client machine which has no FCU.
System Switch 1A (SP No. 1-101-027)
No
Function
Comments
0
to
7
LS RX memory capacity threshold
setting
00-FF (0-1020 Kbyte: Hex)
Sets the value to x4KB. When the amount of available
memory drops below this setting, RX documents are
printed to conserve memory.
Initial setting 0x80 (512 KB)
NOTE: If a customer wants available memory size to
be larger, decrease this threshold
System Switch 1B - Not used (do not change these settings)
System Switch 1C - Not used (do not change these settings)
System Switch 1D (SP No. 1-101-030)
No
Function
Comments
4. Service Tables
104
Summary of Contents for Type M12
Page 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Page 2: ......
Page 10: ...8...
Page 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Page 50: ...2 Replacement and Adjustment 48...
Page 84: ...3 Troubleshooting 82...
Page 218: ...5 Detailed Section Descriptions 216...