Bit Switches - 6
• Do not adjust a bit switch or use a setting that is described as "Not used", as this may cause the
machine to malfunction or to operate in a manner that is not accepted by local regulations. Such
bits are for use only in other areas, such as Japan.
Default settings for bit switches are not listed in this manual. Refer to the System Parameter List printed by
the machine.
IP Fax Switches
IP Fax Switch 00 (SP No. 1-111-001)
No.
Function
Comments
0
Not used
Do not change this setting.
1
IP Fax Transport
0: TCP, 1: UDP
Selects TCP or UDP protocol for IP-Fax
2
IP Fax single port selection
0: OFF, 1: ON (enable)
Selects single data port.
3
IP Fax double ports (single data port)
selection
0: OFF, 1: ON (enable)
Selects whether IP-Fax uses a double port.
4
IP Fax Gatekeeper
0: OFF, 1: ON (enable)
Enables/disables the gatekeeper for IP-Fax.
5
IP Fax T30 bit signal reverse
0: LSB first, 1: MSB first
Reverses the T30 bit signal.
6
IP Fax max bit rate setting
0: Not affected, 1: Affected
When "0" is selected, the max bit rate does not
affect the value of the DIS/DCS.
When "1" is selected, the max bit rate affects the
value of the DIS/DCS.
Bit Switches - 6
151
Summary of Contents for Type M12
Page 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Page 2: ......
Page 10: ...8...
Page 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Page 50: ...2 Replacement and Adjustment 48...
Page 84: ...3 Troubleshooting 82...
Page 218: ...5 Detailed Section Descriptions 216...
Page 226: ...MEMO 224 EN...