3. Troubleshooting
Error Codes
If an error code occurs, retry the communication. If the same problem occurs, try to fix the problem as
suggested below. Note that some error codes appear only in the error code display and on the service
report.
Code
Meaning
Suggested Cause/Action
0-00
DIS/NSF not detected within 40 s
of Start being pressed
• Check the line connection.
• The machine at the other end may be
incompatible.
• Replace the FCU.
• Check for DIS/NSF with an oscilloscope.
• If the rx signal is weak, there may be a bad line.
0-01
DCN received unexpectedly
• The other party is out of paper or has a jammed
printer.
• The other party pressed Stop during
communication.
0-03
Incompatible modem at the other
end
The other terminal is incompatible.
0-04
CFR or FTT not received after
modem training
• Check the line connection.
• Try changing the tx level and/or cable equalizer
settings.
• Replace the FCU.
• The other terminal may be faulty; try sending to
another machine.
• If the rx signal is weak or defective, there may
be a bad line.
Cross reference
Tx level - NCU Parameter 01 (PSTN)
Cable equalizer - G3 Switch 07 (PSTN)
Dedicated Tx parameters in Service Program Mode
49
Summary of Contents for Type M12
Page 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Page 2: ......
Page 10: ...8...
Page 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Page 50: ...2 Replacement and Adjustment 48...
Page 84: ...3 Troubleshooting 82...
Page 218: ...5 Detailed Section Descriptions 216...
Page 226: ...MEMO 224 EN...