Address
Function
Unit
Remarks
68053F
Country dial tone upper frequency limit
(HIGH)
Hz (BCD)
If both addresses contain
FF(H), tone detection is
disabled.
680540
Country dial tone upper frequency limit
(LOW)
680541
Country dial tone lower frequency limit
(HIGH)
If both addresses contain
FF(H), tone detection is
disabled.
680542
Country dial tone lower frequency limit
(LOW)
680543
Country dial tone detection time
20 ms
If 680543 contains FF, the
machine pauses for the
pause time (680548 /
680549).
680544
Country dial tone reset time (LOW)
680545
Country dial tone reset time (HIGH)
680546
Country dial tone continuous tone time
-
-
680547
Country dial tone permissible drop time
20 ms
-
680548
Country dial wait interval (LOW)
680549
Country dial wait interval (HIGH)
68054A
Time between opening or closing the
DO relay and opening the OHDI relay
1 ms
See Notes 3, 6 and 8.
SP2-103-012 (parameter
11).
68054B
Break time for pulse dialing
1 ms
See Note 3.
SP2-103-013 (parameter
12).
68054C
Make time for pulse dialing
1 ms
See Note 3.
SP2-103-014 (parameter
13).
68054D
Time between final OHDI relay closure
and DO relay opening or closing
1 ms
See Notes 3, 6 and 8.
SP2-103-015 (parameter
14).
This parameter is only valid
in Europe.
4. Service Tables
166
Summary of Contents for Type M12
Page 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Page 2: ......
Page 10: ...8...
Page 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Page 50: ...2 Replacement and Adjustment 48...
Page 84: ...3 Troubleshooting 82...
Page 218: ...5 Detailed Section Descriptions 216...
Page 226: ...MEMO 224 EN...