System Switch 11 (SP No. 1-101-018)
No
Function
Comments
0
TTI printing position
0: Superimposed on the page data
1: Printed before the data leading
edge
Change this bit to 1 if the TTI overprints information
that the customer considers to be important (G3
transmissions).
NOTE: If "1" is selected, it is possible that sent data is
printed on two sheets of paper.
1-2
Not used
Do not change these settings.
3
TTI used for broadcasting
0: The TTIs selected for each Quick/
Speed dial are used
1: The same TTI is used for all
destinations
1: The TTI (TTI_1 or TTI_2) which is selected for all
destinations during broadcasting.
4-7
Not used
Do not change these settings.
System Switch 12 (SP No. 1-101-019)
No
Function
Comments
0-7
TTI printing position in the main scan
direction
TTI: 08 to 92 (BCD) mm
Input even numbers only.
This setting determines the print start position for the
TTI from the left edge of the paper. If the TTI is moved
too far to the right, it may overwrite the file number
which is on the top right of the page. On an A4 page,
if the TTI is moved over by more than 50 mm, it may
overwrite the page number.
System Switch 13 - Not used (do not change these settings)
System Switch 14 - Not used (do not change these settings)
System Switch 15 (SP No. 1-101-022)
No
Function
Comments
0
Not used
Do not change the settings.
4. Service Tables
102
Summary of Contents for Type M12
Page 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Page 2: ......
Page 10: ...8...
Page 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Page 50: ...2 Replacement and Adjustment 48...
Page 84: ...3 Troubleshooting 82...
Page 218: ...5 Detailed Section Descriptions 216...
Page 226: ...MEMO 224 EN...