Address
Function
Unit
Remarks
680524
PABX detection time for silent period
after ringback tone detected (LOW)
20 ms
If both addresses contain
FF(H), tone detection is
disabled.
680525
PABX detection time for silent period
after ringback tone detected (HIGH)
20 ms
680526
PABX busy tone frequency upper limit
(high byte)
Hz (BCD)
If both addresses contain
FF(H), tone detection is
disabled.
680527
PABX busy tone frequency upper limit
(low byte)
680528
PABX busy tone frequency lower limit
(high byte)
Hz (BCD)
If both addresses contain
FF(H), tone detection is
disabled.
680529
PABX busy tone frequency lower limit
(low byte)
68052A
Busy tone ON time: range 1
20 ms
-
68052B
Busy tone OFF time: range 1
68052C
Busy tone ON time: range 2
68052D
Busy tone OFF time: range 2
68052E
Busy tone ON time: range 3
68052F
Busy tone OFF time: range 3
20 ms
680530
Busy tone ON time: range 4
680531
Busy tone OFF time: range 4
680532
Busy tone continuous tone detection
time
4. Service Tables