ITU-T T1 time (for PSTN G3 mode)
If the connection time to a particular terminal is longer than the NCU parameter setting, adjust this
byte. The T1 time is the value stored in this byte (in hex code), multiplied by 1 second.
Range:
0 to 120 s (00h to 78h)
FFh - The local NCU parameter factory setting is used.
Do not program a value between 79h and FEh.
Switch 01
No
FUNCTION
COMMENTS
0-4
Tx level
If communication with a particular remote
terminal often contains errors, the signal
level may be inappropriate. Adjust the Tx
level for communications with that terminal
until the results are better.
If the setting is "Disabled", the NCU
parameter 01 setting is used.
• Do not use settings other than listed
on the left.
Bit4
Bit3
Bit2
Bit1
Bit0
0
0
0
0
0
0
0
0
0
0
1
–1
0
0
0
1
0
–2
0
0
0
1
1
–3
0
0
1
0
0
–4
0
1
1
1
1
–15
1
1
1
1
1
Disabled